Before you start...
Check location
where dryer will be installed
Proper installation
is your responsibility.
The dryer
must not be installed
or stored in an area where
it will be exposed
to water and/or
weather.
Make sure you have everything
necessary
for
correct
installation.
Thls appliance
must be attached to a wall.
The
cable
bracket
must be secured
to a wall stud
or concrete
wall within a 24 inch-wide
area
that is 28 inches minimum
to 4 1 inches
maximum
from floor. (See Panel C.)
Proper gas and electric supply connectlons
should be available.
Protectlon tram
the
weather:
Proper operation
of dryer cycles requires temperatures
above
45"F., or the dryer may not shut off when
automatic
cycles are used.
Four-inch metal exhaust duct is
required.
Support:
The floor must be able to support
dryer
weight
of 175 pounds,
Check code requlrements:
Some codes
limit or
do not permit Installation
of clothes
dryers in
garages,
closets, mobile
homes, or sleeping
quarters.
Contact
your local building
inspector.
Open dryer and remove
literature
and parts
packages.
level tloor:
1 -inch maximum
floor slope under
dryer.
entire
max.
Dryer door clearances
-D
Location
must be large enough
to fully open
dryer door.
See back cover ot lnstallatlon
lnstructlons or label on dryer rear panel tor
recessed and closet requlrements.
Tools and materials
needed for
Installation:
4" metal exhaust
duct
gas supply connection
kr 31
male pipe thread
Gas supply
requirements
Fire Hazard
l
Thls dryer must be connected
to a
regulated gas supply. Failure to do so
could cause hlgh-pressure gas release,
resulting In a flre or explosion.
l
Have the L.P. gas checked by a qualltled
person betore lnstalllng the dryer. The L.P.
gas supply must not exceed a pressure ot
134nch water column.
l
New flexible tublng should be used.
Reuslng old flexible tublng mlght result In
possible leaks or fire hazard.
Failure to
r0ii0w
these lnstructlons may result
In flre or exploslon.
OBSERVE ALL GOVERNING CODES AND
ORDINANCES.
,gas burner inlet
pipe connection
at rear ot dryer
23"
r
Important:
Observe all
governing codes and
ordinances.
Sldedzring
A
1 This installation
must conform
with
American
National
Standard,
National
Fuel Gas
Code ANSI 2223.1 - latest edition,
and all local
codes and ordinances,
B
n
The design of this dryer has been
certified
by the American
Gbs Association
for
use at altitudes
up to 10,ooO feet above
sea
level at the B.T.U. rating indicated
on the
serial/rating
plate.
Burner input adjustments
are
not required
when the dryer is operated
up to
this elevation.
When installed
above
1 O,ooO feet, a four
percent
(4%) reduction
of the burner B.T.U.
rating shown on the serial/rating
plate is
required
for each
1 X00 foot increase
in
elevatlon.
For assistance
when converting
to
other gas types and/or
Installing above
10,000
feet elevation
contact
your local service
company.
C
n
Check the
It
dryer is equipped
with the correct
burner for the
particular
type of
gas in the home.
Burner information
will be found on
the serial/rating
plate in door well
-I
of the appliance.
If this information
does not
agree
with the type of gas available,
see your
dealer,
D
n
This dryer is equipped
for use with
NATURAL GAS. It is design-certified
by A.G.A.
for L.P. (propane
or butane)
gases with
appropriate
conversion.
No attempt
shall be
made
to convert
the appliance
from the gas
specified
on the serial/rating
plate for use with
a different
gas without
consulttng
the serving
gas supplier.
Converslon must be done by a
quallfled service technlclan.
Gas conversion
klt part numbers are llsted on the gas valve
burner base.
L
Fire Hazard
For your safety the information
in this
manual must be followed to minimize
the risk of fire or explosion or to
prevent property damage,
personal
injury or loss of life.
- Do Not store or use gasoline or
other flammable
vapors and liquids
in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
l
Do Not try to light any appliance.
l
Do Not touch any electrical
switch; Do Not use any phone in
your building.
l
Clear the room, building or area
of all occupants.
l
Immediately
call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
l
If you cannot reach your gas
supplier, call the fire department.
- Never install dryer up against
draperies or curtains or on carpet.
- Keep any and all items from falling
or collecting
behind the dryer.
Installation and service must be
performed
by a qualified installer,
service agency or the gas supplier.
Fire Hazard
lt you Install the dryer In a garage, car-port,
or areas near vehicles where tumes tram
gasoline or other tlammable materials may
be present, the vapors may be heavier than
alr and remain near rloor. Place dryer a
mlnlmum ot 18 Inches above floor. Check
wlth your bulldlng Inspector regarding
requirements tar thls Installation.
Failure to tallow these lnstructlons could result
In tire or exploslon.
E
H Provide a
rlgld gas supply line
to the
dryer location.
When rigid pipe is used it should
be l/2 inch IPS. When acceptable
to the gas
supplier
and local codes,
3/8-inch
approved
tubing
may be used for lengths under 20 feet.
For lengths over 20 feet, larger tubing
should be
used.
Pipe-joint
compounds
resistant to the
action
of L.P. gas must be used.
shutoff valve
"open"
position
t
n
The supply line shall be equipped
with a
shutoff valve.
This valve should be located
in
the same room as the dryer and should be in a
location
that allows the valve to be opened
and closed easily. Do not block access
to
shutoff valve.
G
n
If the dryer is installed
in a confined
area such as a bedroom,
bathroom
or closet,
provision
must be made
for enough
air for
combustion
and ventilation.
Check
governing
codes and ordinances,
Also, check
recessed
and closet installation
instructions
section
or
label on dryer rear panel
for detailed
instructions.
H
n
If local codes
permit,
it is
recommended
that new
flexible
metal tubing,
design-certified
by the
American
Gas
Association,
be used for
connecting
the
\\
appliance
to the rigid gas
red cap
supply Ilne.
(The gas pipe which extends
through the lower rear ot the appliance
has
3/84nch male pipe thread.)
I
n
If rigld p
supply line, a
fittings must be use
in-line connection
to the dryer.
Panel A