Whirlpool YWED85HEFC2 Інструкція з монтажу Посібник з монтажу - Сторінка 6
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Сушарка Whirlpool YWED85HEFC2. Whirlpool YWED85HEFC2 48 сторінок.
Installation Clearances
For each arrangement, consider allowing more space for ease
of installation and servicing, spacing for companion appliances,
and clearances for walls, doors, and floor moldings. Space
must be large enough to allow door to fully open. Add spacing
on all sides of dryer to reduce noise transfer. If a closet door
or louvered door is installed, top and bottom air openings
in door are required.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
Installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum
spacing allowed.
Additional spacing should be considered for ease of
■
installation and servicing.
Additional clearances might be required for wall, door,
■
floor moldings, dryer venting, and gas line.
Additional spacing should be considered on all sides
■
of the dryer to reduce noise transfer.
For closet installation with a door, minimum ventilation
■
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
Companion appliance spacing should also be considered.
■
Recommended installation clearances (dryer only):
18" min.
(457 mm)
0–5"
(0–127 mm)
1"
(25 mm)
0" (0 mm) rear spacing is allowed for straight back venting only.
For steam models only, inlet hose must not be kinked.
Minimum installation clearances (dryer only):
Front
Recessed
NA
Closet
NA
*0" (0 mm) spacing is allowed for straight back venting only.
6
3"
(76 mm)
48 in.
(310 cm
24 in.
(155 cm
3"
(76 mm)
1"
(25 mm)
Sides
Rear
0" (0 mm)
0" (0 mm)*
0" (0 mm)
0" (0 mm)
0" (0 mm)*
0" (0 mm)
Custom under-counter installation:
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile home
construction and Safety, Title 24, HUD Part 280) or Standard
CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, available for purchase
■
from your dealer. For further information, see "Assistance
or Service" in your Use and Care Guide.
Special provisions must be made in mobile homes to
■
introduce outside air into dryer. Openings (such as a
nearby window) should be at least twice as large as dryer
exhaust opening.
For mobile home installation of gas dryers:
Mobile Home Installation Hold-down Kit Part Number 346764
■
is available to order. For further information, see "Assistance
or Service" in your Use and Care Guide.
min.
2
)
2
min.
2
)
2
Top