9. Install the 4 - #10 x
" mounting screws in pilot holes. Leave
about
" (6.4 cm) space between screw heads and cabinet
to slide range hood into place.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
10. For Direct Wire Installations:
Disconnect power.
Install a UL listed or CSA approved strain relief.
A. UL listed or CSA approved strain relief
Pull about 12" (30 cm) of wire through wall or cabinet and
into opening.
For Power Supply Installations:
Follow instructions included with power supply cord kit
marked for range hoods.
11. Using 2 people, lift range hood into final position, feeding
electrical wire through wiring opening. Position the range
hood so that the large end of the keyhole slots are over the
screws. Then push the hood toward the wall so that the
screws are in the neck of the slots. Tighten mounting screws
to cabinet, making sure mounting screws are in narrow neck
of slots.
12. Check that damper, if used, rotates up and down freely.
13. For Vented Installations Only:
Connect ventwork to hood. Seal joints with clamps to make
secure and airtight.
10
"
(6.4 mm)
A

Make Electrical Connection

1. Run 3 wires, black, white, green or bare through strain relief,
into terminal box. Use caulking to seal openings.
D
F
A. White wires
B. Black wires
C. UL listed wire connectors
D. Ground wires
E. UL listed or CSA approved strain relief
F. Green ground screws
2. Use UL listed wire connectors and connect the 4 white wires
(A) together (2 wires from the range hood controls, 1 wire
from the range hood motor, and 1 wire from the home supply
cable).
3. Use UL listed wire connectors and connect black wires (B)
together.
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
4. Connect the 2 ground wires (D) (green or bare) of home
power supply and range hood to the green ground screws (F)
in the terminal box.
5. Tighten strain relief screws.
6. Install the terminal box cover.
7. Reconnect power.