Whirlpool UXL6036YSS0 Інструкція з монтажу та інструкція з експлуатації та догляду - Сторінка 11

Переглянути онлайн або завантажити pdf Інструкція з монтажу та інструкція з експлуатації та догляду для Вентиляційна витяжка Whirlpool UXL6036YSS0. Whirlpool UXL6036YSS0 36 сторінок. 36" (91.4 cm) and 48" (121.9 cm) hood liner

Whirlpool UXL6036YSS0 Інструкція з монтажу та інструкція з експлуатації та догляду
Complete
Preparation
1. Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall,
do not damage electrical wiring or other hidden utilities.
2. Determine the location where the 1/2"(1.3 cm) wiring conduit
will be routed through the ceiling or wall between the in-line
blower and the hood liner.
3. Drill a 1V4" (3.2 cm) hole at this location.
4. Locate the electrical terminal boxes in the in-line blower
housing and hood liner. Remove the terminal box covers and
set the covers and screws aside.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
A
A. Electrical terminal box
B. Electrical knockout
5. Remove the electrical knockout from the in-line blower
housing and hood liner to prepare for the installation of the
UL listed or CSA approved 1/2"(1.3 cm) wiring conduit and
conduit connector.
6. With the hood liner mounted (see the "Install Hood Liner"
section), run the 1/2"(1.3 cm) wiring conduit between the in-
line blower motor housing and the hood liner. Pull enough
1/2"(1.3 cm) wiring conduit to allow for easy connection to the
terminal boxes in the in-line blower housing and hood liner.
7. Run the six 18 AWG wires through the 1/2"(1.3 cm) wiring
conduit and conduit connectors
and into the terminal boxes
on the in-line blower housing and hood liner. Leave enough
wire length in each terminal box to make the wiring
connections.
8. Install the conduit connectors and conduit to the in-line
blower housing and hood liner electrical terminal boxes.
9. Connect the vent system to the hood liner and in-line blower
system and seal all joints with clamps.
Electrical
Connection
Inside In-line Blower System
1. Disconnect
power.
2. Connect the wires from the wiring conduit to the wires from
the motor electrical plug cable inside the in-line blower
housing terminal box.
B
C
A
A. UL fisted or CSA approved
E Blue wires
½" (1.3 cm) wiring conduit
G. Gray wires
B. UL fisted wire connectors
H. Green (or yellow/green)
C. Black wires
and green/yellow
wires
D. White wires
I. Motor electrical plug cable
E. Red wires
3. Use UL listed wire connectors
and connect the black wires
(C) together.
4. Use UL listed wire connectors
and connect the white wires
(D) together.
5. Use UL listed wire connectors
and connect the red wires (E)
together.
6. Use UL listed wire connectors
and connect the blue wires (F)
together.
7. Use UL listed wire connectors and connect the gray wires (G)
together.
11