FireRock 42 inch Outdoor Інструкція з монтажу Посібник з монтажу - Сторінка 6

Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Внутрішній камін FireRock 42 inch Outdoor. FireRock 42 inch Outdoor 9 сторінок. Fire box

Broken Components 
Components that become broken due to poor handling or shipping should be mortared back together 
providing the breaks or cracks are clean and original alignment and dimension can be maintained.  
Components broken into multiple pieces or fragments must be discarded and replaced. 
 
Hints 
a. If this is your first emberlok installation, it would only take a few minutes to "dry stack" (erect 
without mortar)your firebox to gain a better understanding of how the components fit together.  
Then disassemble and erect using mortar. 
b. Use a level to assure all components are level and plumb as you erect your fireplace and 
chimney. 
c. Assure your baseplate is level and at the proper elevation so the finished hearth height 
(including firebrick lining) is correct. 
d. Realize that this is a TWO man job!  Some of the components are too heavy for one man to lift. 
e. ALWAYS INSTALL ACCORDING TO LOCAL CODES 
 
Gas Line Applications 
The emberlok fireplace may be drilled through with an ordinary masonry drill bit to accommodate a 
natural gas connection.  This natural gas connection may be used to 1) incorporate an automatic shut‐
off device and/or 2) comply with the Standard for Decorative Gas Appliances for Installation in Vented 
Fireplaces, ANSI Z21.60 or ANSI Z21.11.2.  The decorative gas appliance should be installed in 
accordance with the National Gas Fuel Code, ANSI Z223.1. 
 
 
 
 
IN – FIELD APPLICATION 
Assembly views on the following pages