OPERATING MODES

The sequencer has 5 operating modes.
Equal : Different : Clock : Step : Burst

EQUAL MODE

Equal Mode sets the same interval between all channels.
The channels can be fired in groups. Each successive Trigger Input will fire the next group of
channels. After all channels are fired the Trigger Output will fire on each successive Trigger
Input pulse. This is to enable linking multiple sequencers for longer sequences.
Example 1
[1 Group of 18 Channels]
Channel 1 - 18 will fire with 1.5 seconds between each channel when the 1
Trigger Input is
st
received.
Trigger Output will then fire on each successive Trigger Input.

Example 2

[3 Groups of 6 Channels]
Channel 1 - 6 will fire with 5 seconds between each channel when the 1
Trigger Input is
st
received.
Channel 7 - 12 will fire with 5 seconds between each channel when the 2
Trigger Input is
nd
received.
Channel 13 - 18 will fire with 5 seconds between each channel when the 3
Trigger Input is
rd
received.
Trigger Output will then fire on each successive Trigger Input.