4. Balance values
Sensor 1
Temperature:
Min
23.8 ° C
Max
172.0 ° C
Pressure:
Min
0.14 bar
Max
0.14 bar
Flow rate:
Min 5.55
l/min
Max 6.11
L/min
Acc 4322.7 l
In this submenu, the balance values for "Sensor 1", "Sen-
sor 2" and "Others" are indicated. When "Heatmeter" has
previously been set to "Yes" in the submenu "Adj. values",
the balance values for this item are also indicated. The bal-
ance values refer to the period of time the device has been
in use. If these values are reset to zero, a new operating
period starts.
balance values
heatmeter
heat
balance values
others
operating days
5. Adjustment values
8
|
Sensor 2
Temperature:
Min
0.0 ° C
Max
23.9 ° C
Diff-Pressure:
Min
0.14 bar
Max
0.14 bar
62254 Wh
0
Note:
The indicated balance values depend on the
selected sensor type!
Display of balance values "Sensor 1":
• Temperature:
Min: minimum temperature at sensor 1 in ° C or ° F
Max: maximum temperature at sensor 1 in ° C or ° F
• Pressure:
Min: minimum pressure at sensor 1 in bar
Max: maximum pressure at sensor 1 in bar
• Diff-Pressure:
Min: minimum differential pressure at sensor 1 in bar
Max: maximum differential pressure at sensor 1 in bar
• Flow rate:
Min: minimum flow rate at sensor 1 in l/min, m³/h, gallon/h
Max: maximum flow rate at sensor 1 in l/min, m³/h, gallon/h
Acc: accumulated volume since commissioning / last re-
set in l, m³ or gallons
Display of balance values "Sensor 2":
• Temperature:
Min: minimum temperature at sensor 2 in ° C or ° F
Max: maximum temperature at sensor 2 in ° C or ° F
• Pressure:
Min: minimum pressure at sensor 2 in bar
Max: maximum pressure at sensor 2 in bar
• Diff-Pressure:
Min: minimum differential pressure at sensor 2 in bar
Max: maximum differential pressure at sensor 2 in bar
• Flow rate:
Min: minimum flow rate at sensor 2 in l/min, m³/h, gallon/h
Max: maximum flow rate at sensor 2 in l/min, m³/h, gallon/h
Acc: accumulated volume since commissioning / last re-
set in l, m³ or gallons
Display of balance values "Heatmeter":
• Heat:
Heat quantity in Wh, kWh, MWh, kJ, MJ or GJ.
Display of balance values "Others":
• Operating days:
Number of operating days
In this menu the parameters and values for Sensor 1 and
Sensor 2, heat quantity measurement and bus mode can be
selected and adjusted. Furthermore, date and time have to
be set in this menu, see chap. 2.3.
Each sensor has two signals. The first signal of each sensor
refers to temperature. The second signal of each sensor
depends on the sensor type which can either be VFS for
flow rate, RPS for relative pressure or DPS for differential
pressure.