Amendment to Installation
Instructions Compact 3020 HE
This document refers to clauses of Installation instructions Compact 3020 HE, V-3020
01 rev 1717 and adapts them, indicating the changes by stating "with the following
modification", "with the following addition", "is replaced with the following", "as it is
stated" or "is not applicable". It also adds clauses or sub-clauses to the structure of
Installation instructions Compact 3020 HE, V-3020 01 rev 1717 which are particular to
this amendment, V-3020 07 rev 1751. When applicable, the word "vehicle" could also
mean "small craft".
In the United Kingdom of Great Britain and Northern Ireland, installers should refer to
BSI PD 54823 and adhere to rules and regulations laid out in GSUIR and BSS.
All safety information is marked with this symbol and shall be regarded
even if the installation section is not applicable.
1. Intended use
With the following modification;
- Only to be installed in small crafts used
in inland waterways and only during con-
ditions with maximum waves according to
Beaufort Scale 2.
- Always follow relevant sections of ISO
10239 Small craft – Liquefied petroleum
gas (LPG) systems.
2. Prohibited use
With the following modification:
Not to be used in any other crafts other
than Canal or Narrow boats.
3. Safety features
As it is stated.
4. Technical data
As it is stated.
5. Installation instruction Alde
Compact 3020 HE
5:1 Important information
As it is stated.
5:2 Planning the heating system
As it is stated.
5:3 Boiler installation
"When placing outside the vehicle"
Is replaced with the following:
"Only to be installed indoors in a dry
compartment, not the engine compartment."
5:4 Fitting a roof flue
With the following addition:
There must be a minimum lateral distan-
ce of 500 mm from a refueling point or
fuel tank breather outlet or any ventilator
outlet from the fuel system(s).
5:5 Fitting a wall flue
With the following addition:
All holes in the hull should be at least 250
mm above the "normally laden waterline".
• Must not be positioned within 500 mm of
vents, opening ports or hatch windows.
• Must not be positioned within an enclo-
sed canopy.
• Must be continuous and sealed from the
appliance to terminal.
• Entire length must be accessible for
inspection.