CLARIUS EP PLUS VEP-CW30-PC Посібник з монтажу - Сторінка 5
Переглянути онлайн або завантажити pdf Посібник з монтажу для Прожектор CLARIUS EP PLUS VEP-CW30-PC. CLARIUS EP PLUS VEP-CW30-PC 6 сторінок. Led floodlight
3. MAINTENANCE
1.
Isolate the Clarius EP Plus unit from the mains supply and allow it to cool before carrying out
any maintenance work.
2.
In the unlikely event of the failure of a string of LED's (6 or 8), the assembly must be re
placed. Contact GJD for immediate assistance and advice.
3.
It is essential that all Clarius EP Plus units are maintained in accordance with the
requirements of the EN60079-17 standard: Electrical apparatus for explosive gas
atmospheres – other than mines.
4.
IMPORTANT! No modifications are permitted to the unit. All spare parts must be purchased
from the manufacturer or authorized distributor. Any unauthorized modifications or spare
parts may make the apparatus dangerous and invalidate certification.
5.
ELECTROSTATIC CHARGING HAZARD - Plastic components may be cleaned with water
containing a small amount of detergent, followed by a clean water wash. Surplus water
can be wiped off plastic components, but they should not be wiped or polished with a dry
cloth to avoid a build-up of static electricity. Strong cleaning solvents could cause damage
to plastic components.
6.
Disposal of packaging, Clarius EP Plus units and old LED assemblies should be carried out in
accordance with national regulations.
4. TECHNICAL SPECIFICATION
CERTIFICATION
II 2 G D Ex emb IIC T4 Gb
Ex t IIIC T103°C Db IP66/67
Ta = -20°C to +50°C
Clarius EP Plus SPECIFICATION
Input Voltage
Consumption
Power Factor
Mains Frequency
IP Rating
Single Unit Weight
Dimensions
ATEX and IECEx Rating
Tel: +44 (0) 1706 363 998
SIRA09ATEX5159X
IECEx SIR09.0064X
ABS 11-LD801943-PDA
24V AC/DC or 100-240V AC
60W max
>0.95 or better
50/60Hz
66/67
6Kg per module
250 135 x 315mm
Zone 1 gas and dust hazardous environments