CLARIUS STAR - INSTALLATION AND OPERATING INSTRUCTIONS
The Clarius Star floodlight is a low energy high power outdoor LED floodlight which is suitable for Installation on
solid walls in a range of locations including entrances, gardens, staircases, garages and outdoor parking areas.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN AND CHECKED FOR SAFE
OPERATION BEFORE USE
PLEASE FOLLOW THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS LIGHT
The unit requires connection to a 170-240VAC 50Hz mains electrically supply.
This risk of electric shock should be minimized by the installation of appropriate safety devices including the
incorporation of an RCCB (Residual Current Circuit Breaker) into the main distribution board.
DO NOT wire this floodlight directly into the lighting circuit. Use a switched fused spur. Cables should always be
protected against short circuit and overload by use of an RCD.
Ensure the voltage marked on the product is the same as the electrical power supply to be used.
DO NOT install the floodlight where it is likely to be knocked, hit or near an exhaust outlet e.g. boiler flue, dryer
outlet.
This floodlight is suitable for outdoor lighting applications, for domestic use only. Do not use in areas where an
explosive or chemical atmosphere may exist. Do not use in areas where ventilation is restricted.
POSITIONING
The Clarius Star is suitable for mounting on plasterboard, wood or masonry surfaces. Highly flammable surfaces such
as plastic or polystyrene must not be used. Do not install on damp or conductive surfaces such as metal. It should be
placed away from any flammable materials.
Ensure that there is space around the floodlight to allow adequate circulation of air.
Before drilling any fixing holes, check that there are no hidden obstructions behind the mounting surfaces such as
pipes or cables.
The recommended height for installation of the floodlight is between 3-5 metres.
The floodlight can be orientated vertically or horizontally as shown:
Horizontally
When mounted horizontally ensure that the
removable access cover is to the under side
PIR SENSOR POSITIONING
LESS EFFECTIVE
Movement directly towards or away from scan area
INSTALLATION TO BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN
The floodlight is suitable for connection to a 170-240VAC, 50Hz, earthed supply. It is designed for permanent
connection to fixed wiring, which must be a suitable circuit protected by an RCD and fuse of the correct rating.
Ensure that the mains supply is switched off before commencing installation.
It is recommended that the unit is connected to the domestic lighting circuit via a 5 Amp fused spur and using
3-core round flexible cable of at least 1mm
It is also advisable to install a single pole wall switch to allow easy control of the floodlight.
Before commencing installation check that you have all the tools that you need.
Check that the floodlight and its mains lead are not damaged. If there is any damage, return it to the place of
purchase. Do not attempt to repair it yourself.
Choose your location to fix the floodlight, taking into account the guidance above.
Use the floodlight bracket to mark the position of the fixing holes.
Vertically
Drill the fixing holes and fix the floodlight into position using the screws and wall plugs provided.
Check that is securely fixed.
Connect the mains lead from the floodlight to an IP rated junction box. Ensure that the correct polarities for
Live, Earth and Neutral are observed i.e.
After wiring, check that there are no bare wires, all the wires have been correctly connected and that the cable
restraint has been tightened.
Before connecting power, perform the electrical tests specified in the current building and IET Wiring
regulations to ensure that the installation is safe and that the wiring has been performed correctly.
Switch on the electricity to check that floodlight illuminates. Adjust the angle of the floodlight so that it
illuminates the required area. Tighten the floodlight brackets.
4M
8M
10M
120º
gauge (waterproof cable should be used for outdoor installations).
2
Connect the green/yellow earth wire to the terminal 'E'
Connect the brown live wire to the live terminal 'L'
Connect the blue neutral wire to the neutral terminal 'N'
MOST EFFECTIVE
120º
Movement across the scan area