CALI neonLEDs NLED Інструкція з монтажу Посібник з монтажу - Сторінка 8
Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Освітлювальне обладнання CALI neonLEDs NLED. CALI neonLEDs NLED 12 сторінок. Neonleds series
neonLEDs
Installation Instructions
TROUBLESHOOT
• Do not reset breaker multiple times.
• If the unit is overloaded the breaker will trip shutting off the
transformer and lights.
• If the breaker reset button has been held down by hand or any type
of pressure (example: duct tape), or if the breaker has been reset
multiple times without trouble shooting, the unit will:
- Burn the transformer bobbin
- Burn the primary or secondary wires due to high amperage caused
by overload and/ or short circuit in line which will not allow the
breaker to reset
- Damage the lighting
1.
Turn off power before beginning. Check for any twisting or damage to
the circuit in the neonLED. If there is excessive damage and
circuit is broken, the lightstrip must be replaced.
Torn lightstrip
2.
Check for metal particles or other foreign objects causing the short.
Metal flakes
Metal flakes
Brown
(Hot)
Brown
3.
Check if cut is clean and not frayed, causing positive and negative
(Hot)
copper nodes to touch.
Frayed end
Green
(Ground)
™
Damaged lightstrip
Twisted lightstrip
Foreign object
Foreign object
CALIFORNIA ACCENT LIGHTING, INC.
2034 E. Lincoln Ave. #431, Anaheim, CA 92806
ph. 800.921.CALI (2254) or 714.535-7900 \ fx. 714.535.7902
[email protected] \ calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
4.
Ensure the run is not too long and overlapping.
Excess lightstrip overlapping and
held down with tape or other force
5.
Ensure copper nodes are not making contact with aluminum extrusion.
Copper nodes touching extrusion
6.
Check for water inside end cap or power connector. Water needs to be
removed before connecting to power.
Water inside power connector
Water inside power connector
Water inside end cap
Water inside end cap
Black (-)
7.
After above items have been checked, refer to continuity test:
Red (+)
Black (-)
(Steps 5 - 7 on page 5).
24VDC
Red (+)
White (-)
Blue (+)
White (-)
Optional Dimmer
Blue (+)
(not included)
NLED-24V
Troubleshooting (24V)
Compromised seal
Compromised seal
Compromised seal
Compromised seal
24VDC
Optional Dimmer
(not included)
8 of 10