Zanussi ZPC 426 DM Інструкція з експлуатації - Сторінка 5

Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Холодильник Zanussi ZPC 426 DM. Zanussi ZPC 426 DM 10 сторінок.

Zanussi ZPC 426 DM Інструкція з експлуатації
D151

Fitting door panels

To fit the door panel, proceed as follows:
Loosen the screws fixing the side frame (Fig. 4);
loosen all the other screws fixing the door frame;
insert the panel from the side on which the frame
has been removed and push it through;
refit the frame on the door again and tighten all the
screws.
Note:
The panel size should be 1-2 mm lower than the
door; the maximum panel thickness should be 4 mm.
Fig. 3
5
6
Fig. 4

Building-in

The housing dimensions should be as follows:
Height
1446 mm
Minimum depth
550 mm
Minimum width
560 mm
Cooling air comes in through the ventilation grid at
the bottom of the appliance. To ensure air
circulation, leave a ventilation gap at the back of the
appliance, having the following dimensions:
depth: 50 mm, width: 540 mm (Fig. 5).
A similar gap must also be left in the top of the
kitchen furniture.
Remove the two spacer bushes (A) then fit the
appliance into the recess in the tall kitchen unit.
Using the four screws supplied with the appliance,
secure the four corners of the appliance cabinet
hinge to the tall kitchen unit.
A
D152
Fig. 5
1446
13