Clarke SHHH7 Інструкція з експлуатації та обслуговування - Сторінка 6

Переглянути онлайн або завантажити pdf Інструкція з експлуатації та обслуговування для Повітряний компресор Clarke SHHH7. Clarke SHHH7 10 сторінок. Shhh air compressor

Clarke SHHH7 Інструкція з експлуатації та обслуговування
7.
The Pressure Switch, located within the plastic cover beneath the ON/OFF switch, should
not require adjustment. This is an automatic device and has been preset at the factory
to stop the motor when pressure in the receiver reaches its maximum, and to start it
again when the pressure in the receiver falls to the minimum preset value. This operation
is completely automatic and does not affect the spraying process in any way. However,
should problems develop with the cut-in, cut out settings, please consult your Clarke
dealer, or the Clarke Service Dep't.
NOTE:
a
.
If the machine pumps continuously without cutting out then the compressor is too
small for the application/tool being used, and damage may result. Consult your
Clarke dealer.
b.
The motor is protected by a Thermal Overload so that if the motor overheats for any
reason - the thermal overload will trip, stopping the motor. Allow a period for the
motor to cool down before restarting (15 - 20 minutes).
c.
DO NOT exceed the Duty Cycle for the machine (see Specifications).
SHUTTING DOWN THE COMPRESSOR
1.
To shut off the compressor, simply turn the ON/OFF switch (see Fig. 1), to the O' (OFF)
position.
ALWAYS switch the compressor ON or OFF at the Pressure
Switch...NEVER at the mains supply switch
2.
Close the air outlet tap and trigger the equipment (spray
gun,air tool etc.) to release air from the air hose before
disconnecting the hose from the machine.
3.
Before transporting your compressor or when leaving
overnight, expel all air from the receiver by opening the
drain valve Fig 6. (Does not apply to the SHHH2)
DO NOT FORGET to close the valve again when the tank is empty, particularly if the
compressor may not be used for sojme time.
IMPORTANT:
IMPORTANT:
7
Fig.4