CTEK ONYX Посібник користувача та інструкція - Сторінка 4

Переглянути онлайн або завантажити pdf Посібник користувача та інструкція для Автомобільний зарядний пристрій CTEK ONYX. CTEK ONYX 7 сторінок.

CHARGING PHASES

ONYX is a multi stage fully automatic charger.
Desulphation (Lamp 1, blinking)
Desulphation with pulses to recover sulphated batteries. Indicated by blinking lamp 1.
Start (Lamp 1)
Starting phase for charging. The starting phase continues until the battery's terminal voltage
has risen over a preset level. At this point, charging goes into the bulk phase. If the terminal
voltage has not reached the preset level within 8 hours, charging is suspended. The error mode
is indicated. This indicates a battery which is faulty or has too large capacity. If a large battery
is charged that has been severely discharged, it may be necessary to restart the charger after 8
hours. Start is indicated by lamp 1.
Bulk (Lamp 2)
Primary charging where approximately 80% of the charging happens. The charger delivers
maximum voltage until the terminal voltage has risen to the preset level. After a number of
hours, the charger goes on to the next phase, even if maximum voltage is not reached. Bulk is
indicated by lamp 2.
Absorption (Lamp 3)
Final charging, voltage is kept at the preset level. During this phase, the voltage is gradually
reduced. If the maximum length of time for Absorption is exceeded, the charger automatically
continues with Analysis. Absorption is indicated by lamp 3.
Analysis (Lamp 3)
Charging is suspended for a short period and the battery voltage measured. If it falls too
quickly, the battery is probably faulty. Charging is suspended and an error is indicated (lamp 0).
Maintenance charging - float (Lamp 4)
During the first 10 days of maintenance charging the battery is maintained with constant volt-
age, 13.6V. Float-maintenance is indicated by lamp 4.
Maintenance charging - pulse (Lamp 4)
Charging varies between 95% and 100%. The battery receives a pulse when the voltage drops,
keeping the battery in good shape when it is not being used. The charger can be connected for
months.
If the battery is charged and/or the battery's terminal voltage drops, the charger starts a charge
pulse until the voltage has reached the preset level. The charge pulse is then interrupted and
the cycle is repeated as long as the charger is in pulse maintenance phase. If the terminal
voltage drops even lower, the charger automatically reverts to the beginning of the charging
curve. Pulse maintenance phase is indicated by lamp 4. If possible, check the water level
in the battery.

TEMPERATURE PROTECTION

ONYX is protected from being overheated. The power will be reduced if the ambient tempera-
ture is raised.
EQUIPMENT
ONYX is delivered with a set of battery leads with battery pole clamps and a set of battery leads
with eyelet terminals.