Clarke 7640110 Інструкція користувача - Сторінка 6
Переглянути онлайн або завантажити pdf Інструкція користувача для Інструменти Clarke 7640110. Clarke 7640110 13 сторінок. Shot blast cabinet
• Should any abrasive be spilled, ensure it is cleaned up immediately, as its
slippery properties can be hazardous.
REPLACING THE ABRASIVE NOZZLE
Ensure the air supply is disconnected before performing this operation.
1. Pull the trigger of the gun as a precautionary measure.
2. Unscrew the end cap and withdraw the ceramic nozzle.
3. Replace with the nozzle of your choice and carefully thread the end cap
back on to the gun, taking great care NOT to cross thread the fine thread.
NOTE: Should it be necessary to change the air nozzle, first remove the
abrasive nozzle as described above. A box spanner will be
required to unscrew and withdraw the air nozzle.
MAINTENANCE
Before use, check to ensure that all parts are serviceable, including the air
inlet hose and rubber gloves.
Ensure the air vent foam filter is in place.
The swivel clamps, securing the lid, must be secure so as not to allow the lid to
open during operation. The build up of air pressure within the cabinet could
force the lid open, allowing abrasive to escape. This is not only wasteful, but
could be a health hazard.
Ensure the filters are serviceable and seated correctly.
Ensure you comply with all precautions regarding the use of compressed air,
and air compressor operation.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
6