Input> AES BNC
are continuously monitored so a brief error may not be noticed. When set to
"sticky" an error once set will be continuously displayed even if the signal has
recovered from the error.
Input> AES BNC
Sample rate
Audio bits
Emphasis
Generation
Copyright
Format
Only while reading channel status some sample rates may sound distorted through
the loudspeaker or headphones as it's necessary to switch off some synchronising
functions to efficiently calculate the sample rate.
Input> AES BNC
This displays the first five (and most important) bytes of the AES status word in
binary format.
Errors type>
Ch.Status
Sample rate is calculated directly from the incoming clock.
Possible displayed values are 32kHz, 44.1kHz, 48kHz, 64kHz,
88.2kHz, 96kHz, 176.4kHz and 192kHz. Any other sample rates
will be displayed as '???'.
Possible readable values 16 bit, 20 bit, 24 bit.
On or off.
Original or Copy
Yes or No.
Possible data types PCM, IEC61937, DTS_LD, DTS_CD.
Stat.word
5
loop or sticky
When set to "Loop" any errors
Shows the channel status of the
AES signal. Possible readings are: