Section 1: General Description

Sure-Wave™ hands-free switches are active infrared
devices designed for use with an automatic door operator
or other access control products.
Applications include low-energy doors, drive-up windows,
health-care facilities, manufacturing... etc.
These units will fit in a variety of locations from 1 ¾" door
frames to single and double gang electrical boxes. Various
sized surface mount boxes are available from Camden.
There are 2 Line Powered models available:
CM-331 – Single relay output
CM-332 – Dual relay output
Three standard faceplates widths are available:
Jamb Mount /N: 1 ¾" x 4 ½" polycarbonate or stainless
steel, fits 1 ¾" door frames or our CM-23D jamb box.
Single Gang: 2 ¾" x 4 ½" polycarbonate or stainless
steel, fits on single gang electrical boxes
Double Gang /W: 4 ½" x 4 ½" polycarbonate or stainless
steel, fits on double gang or 4 x 4 electrical boxes.
All faceplates are available with a variety of graphics/text:
/40 Waving Hand symbol
/41 Waving Hand Icon and Wave to open text
/42 Waving Hand Icon, Wave to Open text and
Wheelchair symbol
Light Ring – SGLR Option
Camden CM-331 and CM-332 Sure-Wave are available
with a light ring option. This provides an illuminated ring for
visual confirmation of the switch activation. The light ring
can be set to various combinations of colors, Blue, Blue-
Red, or Green-Red.
CM-331 & CM-332 Series
Active Infrared "Hands-Free" Switches
CM-TX-99 RF Module
Camden CM-331 and CM-332 Sure-Wave can be fitted with
an optional Lazerpoint CM-TX-99 RF Module. The CM-TX-99
RF Module enables the Sure-Wave to product an RF output
when activated, that is compatible with our Lazerpoint
Series receivers.

Section 2: Installation

Mounting
Sure-Wave may be mounted in door jambs, single or double
gang electrical boxes, and 4 x 4 boxes.
NOTE:
The sealing gasket (included) is recommended for outdoor
or wet locations. If using with Automatic doors install in
accordance with ANSI A156.10 / A156.19. Select from one
of the following three mounting subsections:
Single Gang Electrical Box: CM-331 & CM-332
1a – If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
2 – Bring your 4-conductor wire through the back or side
of the enclosure and leave approximately 6" tail for
wiring connection.
3 – Make the electrical connections to the device according
to the wiring section (following).
4 – Using the dip switch located on the end of the unit, set
the operating mode. (See Section 4)
5 – Attach the unit to the enclosure using the two #6-32
screws provided.
6 – Apply power and adjust range and time delay via the
potentiometers on the front of the unit. (See Section 4
for adjustments)
7 – Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!