CAMDEN CM-325/42WS Інструкція з монтажу Посібник з монтажу - Сторінка 5

Переглянути онлайн або завантажити pdf Інструкція з монтажу Посібник з монтажу для Контролер CAMDEN CM-325/42WS. CAMDEN CM-325/42WS 13 сторінок.

WC16PS SERIES RESTROOM CONTROL
I NSTA LLAT I O N I N S T RU C T I O N S
DOUBLE GANG ELECTRICAL BOX MOUNT - CM-331/42SW-SGLR - CM-325/42SW
1. a) If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface.
b) If using a surface box, ensure it is secure & plumb.
c) If using a 4 x 4 box, ensure the box is plumb and square,
and flush with the wall surface, then attach the metal
adaptor plate (included in the packages) to the box using
appropriate fasteners.
2. Bring your 4 or 6-conductor wire through the back or side
of the enclosure and leave approximately 6" tail for
wiring connection.
3. Make the electrical connections to the device according
to the wiring section.
Page 5 of 13
CM-331/42SW-SGLR & CM-325/42SW Flush Mount
CM-331/42S-SGLR Label
Note:
CM-325/42SW Does not
come with a Label
CM-331/42SW-SGLR
CM-325/42SW Faceplate
4. Using the dip switch located on the end of the unit, set the
operating mode.
5. Attach the unit to the enclosure using the two #6-32
screws provided.
6. Apply power and adjust range and time delay via the
potentiometers on the front of the unit.
7. Attach the faceplate to the unit using the two black
#6-32 x 1/2'' machine screws or tamperproof screws.
NOTE: Do not overtighten!
8. Apply the label as required
(only for the CM-331/42SW-SGLR).
Wall
Adapter Plate
5502 Timberlea Blvd.
L4W 2T7
Mississauga, ON Canada
Tel: (905) 366-3377
www.camdencontrols.com
A.OLISA MAR-20
Double Gang Surewave
mounting Exploded