Cable type and minimum section
Connection
Control panel power-supply
Motor power supply
Signaling devices
Command and control devices
Safety devices (photocells)
When operating at 230 V and outdoors, use H05RN-F-type cables that are 60245 IEC 57 (IEC)
compliant; whereas indoors, use H05VV-F-type cables that are 60227 IEC 53 (IEC) compliant. For power supplies up to
48 V, you can use FROR 20-22 II-type cables that comply with EN 50267-2-1 (CEI).
For the Encoderuse 2402C 22AWG-type cables up to 30 m.
For a CRPconnection use UTP CAT5-type cables up to 1,000 m.
Use RG58cable up to 10 m long to connect the antenna.
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power
draw of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according
to the actual power draw and distances. For connecting products that are not contemplated in this manual, see the
literature accompanying said products
INSTALLATION
Tools and materials
Make sure you have all the tools and materials you will need
for installing in total safety and in compliance with applicable
regulations. The figure shows some of the equipment installers
will need.
Fastening the control panel
Fasten the control panel in a protected area;
use rounded cross head screws with maximum
6 mm diameter. maximum 6 mm diameter.
Perforate the punched holes.
The holes have different diameters: 23, 29
and 37 mm.
Be careful not to damage the control board
inside the casing.
Enter the cable gland with the corrugated
tubes for threading the electrical cables.
cable length
< 20 m
20 < 30 m
2
3G x 1.5 mm
3G x 2.5 mm
2
4G x 1.5 mm
4G x 2.5 mm
2 x 0.5 mm2
2 x 0.5 mm2
2 x 0.5 mm2
2