CAME A 5124 Посібник з монтажу - Сторінка 4
Переглянути онлайн або завантажити pdf Посібник з монтажу для Відкривач гаражних дверей CAME A 5124. CAME A 5124 12 сторінок. Automation for swing gates

4.4 Overall dimensions
Measurements in mm
5 Installation
Installation must be carried out by expert qualified personnel and in full compliance with current regulations.
5.1 Preliminary checks
Before installing, do the following:
• Make sure the structure of the gate is sturdy, the hinges work and that the is no friction between moving and non-moving parts;
• That measurement C is not greater than the value shown in Tab. 3, p. 4. In this case you need to work on the pillar until said
measurement is obtained;
• Make sure the path of the electrical cables complies with the command and safety instructions;
• That there is a (soundly secured to the ground) mechanical stop to prevent the gate leaf/gearmotor from over extending.
•
Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation as
compared to the other conductive parts inside;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage.
A 3024 - A 3124
Travel
A 5024 - A 5124
Travel
Pillar
Hinge
Gate leaf width
m
2.00
2.50
3.00
We suggest you always fit an electrolock onto swing gates for a more
reliable closure.
Fitting electrolocks onto reversible operators makes for anti-intrusion
security.
You must install electrolocks onto irreversible operators with gate
leaves exceeding 4 m.
Gate leaf width
m
2.00
2.50
3.00
4.00
5.00
End stop
Gate leaf
Gate leaf weight
kg
800
600
400
Gate leaf weight
kg
1000
800
600
500
400