CAME C-BXE24 Посібник з монтажу - Сторінка 17
Переглянути онлайн або завантажити pdf Посібник з монтажу для Відкривач гаражних дверей CAME C-BXE24. CAME C-BXE24 20 сторінок. Automation for industrial closures
Також для CAME C-BXE24: Посібник (16 сторінок)

Important! For gearmotors installed on
sliding and folding doors, remove the
security lever and respective spring.
5.10 Adjusting end-stops with encoder
Before beginning to make adjustments
on the end-stop, execute the run calibra-
tion procedure described in the technical
manual of the command board.
After calibrating, the door must be in a
closed position and the crown wheel on
the motor unit must be positioned to the
left.
Raise the end-stop spring unhooking it
from the support bracket and lower it
onto the crown wheel.
Important! For gearmotors installed on
sliding and folding doors, never unhook
the end-stop spring from the support
bracket.
Ensure that the release lever is free from
the safety lever.
NB: the safety lever releases the
emergency release (CMS or C002) only
with the door closed.
Safety
lever
Crown wheel
End-stop spring
Safety lever
Release lever
Support bracket
17