Q3 – Operation Manual
As well as speed adjustment there are settings for 'damping'. The 'takeoff' damping sets the
speed of acceleration of the head if the joystick is moved rapidly towards a high speed.
'Slowdown' damping allows the head to decelerate slowly even if the joystick is moved
rapidly back to its centre position. The 'reverse' damping sets how fast the head can
change direction and will override the other damping settings if the joystick is moved from
one direction past the centre point to the opposite direction.
The RCP has a number of additional functions compared to the earlier QBall. There is a
'Bars' test function which is useful when lining up the camera into a studio or OB truck. The
white balance button can now operate in 'Manual Colour Control' mode, i.e. in the same
mode that allows operation of the colour control knobs.
Both Mirror and Flip picture reverses are available. The Flip can be used if the head is
mounted upside down although this is not essential as the head can be turned through
180deg to achieve the same effect!
Another major difference between Q3 and the earlier QBall is that the camera format is set
from the RCP ENG menu. This is described in detail later in this manual.
Also, the OSD (On Screen Display) menus allow access to changing some camera
functions which are not available directly from the RCP. If any changes are made to these
functions not available on the RCP, then they will be saved when exiting from the OSD
menu screen and will remain unchanged even when the 'Update Camera' button is
pressed. These functions include such things as WDR (Wide Dynamic Range), AE Peak,
Eclipse and De-fog.
The other major improvement available with Q3 is the addition of a Genlock function. This
avoids the need for a synchroniser when using Q3 with other cameras into a mixing point.
The timing can be adjusted from the RCP>ENG menu. Vertical timing adjusts by one line
for each setting change (up to a maximum of 15 lines) and Horizontal timing adjusts in pixel
steps. Note that there may be some picture disturbance when making timing adjustments.
The genlock signal can be any analogue video signal with the same frame rate as the
camera format.
The Interface Box also provides a 'composite' video output which will be either PAL or
NTSC depending on the camera format being used. This can be used for feeding a local
SD monitor.

Fiber Card Option

The optional fiber card fits inside the interface box at the rear. If you wish to upgrade a
system to include the fiber card then there is a separate document (supplied with the
upgrade kit), to describe how to fit the card into the interface box.
No external wiring to the interface box connectors is required. The audio data signal on the
fiber is connected internally and the green data LED on the front panel should light as
normal when a data signal is present.
The genlock video signal is also internally connected but DIP 4 must be set to OFF to select
this input rather than the BNC on the rear panel.