4 MAINTENANCE

4.1 PREVENTIVE MAINTENANCE

N/A

4.2 CORRECTIVE MAINTENANCE

4.2.1 TROUBLESHOOTING

Symptom: absence of message acknowledgement outside radio dialogue.
Troubleshooting:
• Make sure the power supplied to the ERCP 81 is within the specified limits,
• Check that the interface's UART is working properly by loop connection of the serial link lines,
• Check the ERCP 81 – interface link: quality of contacts, continuity of wires and protection, etc.
If it turns out that the ERCP 81 is not working, replace it.
Symptom: no valid message in radio dialogue despite proper exchange conditions (see datasheet)
Replace the ERCP 81.

4.2.2 REPLACING AN ERCP 81

1) Remove the ERCP 81:
• Switch off the power supply,
• Disconnect and unscrew the ERCP 81.
2) Replace the ERCP 81:
• Screw the ERCP 81 in,
• Remove the protective plug and connect the ERCP 81,
• Power up.