dIXEL COOL MATE XLH360 Інструкція з експлуатації Посібник з експлуатації - Сторінка 7
Переглянути онлайн або завантажити pdf Інструкція з експлуатації Посібник з експлуатації для Регулятор температури dIXEL COOL MATE XLH360. dIXEL COOL MATE XLH360 16 сторінок. Temperature and humidity controller for seasoning-maturing cabinets
dIXEL
dIXEL
dIXEL
dIXEL
LED
MODE
° C
FLASHING
° F
ON
° F
FLASHING
ON
FLASHING
ON
ON
FLASHING
ON
ON
ON
ON
ON
FLASHING
(umid)
ON
FLASHING
FLASHING
8.2 HOW TO SEE AND MODIFY THE SET POINT (TEMPERATURE AND HUMIDITY)
1.
Push and immediately release the SET key: the display will show the Set point
valueand the correspondant set icon starts flashing;
Or
To change the Set value push the o
2.
3.
To memorise the new set point value push the SET key again or wait 10s.
8.3 TO START A MANUAL DEFROST
1.
Push the DEF key for more than 2 seconds and a manual defrost will start.
8.4 TO START A EXTRACTION CYCLE MANUALLY
Hold pushed the UP key for more than 2 sec.
To stop manually the cycle: when the cycle is running, hold pushed the UP key for more
than 2 sec.
8.5 TO ENTER IN PARAMETERS LIST "PR1"
To enter the parameter list "Pr1" (user accessible parameters) operate as follows:
1.
+
2.
8.6 TO ENTER IN PARAMETERS LIST "PR2"
To access parameters in "Pr2":
1.
Enter the "Pr1" level.
2.
Select "Pr2" parameter and press the " SET %RH " key.
3.
The "PAS" flashing message is displayed, shortly followed by "0 - -" with a flashing zero.
Use o
o or n
n to input the security code in the flashing digit; confirm the figure by pressing " SET %RH ".
4.
o o
n n
The security code is "321".
5.
If the security code is correct the access to "Pr2" is enabled by pressing " SET %RH " on the last digit.
Another possibility is the following: after switching ON the instrument the user can push SET %RH + n
1592017410 XLH360 GB r1.0 15.04.2005.doc
Operating Instructions
FUNCTION
If measurement unit is °C, it flashing on programming mode
°F
If measurement unit is °F, it flashing on programming mode
The compressor is running
- Anti-short cycle delay enabled
The defrost is enabled
Heating enabled
Temperature Set programming phase
- ALARM signal
Fan is running
RH%
Dehumidifying enabled
Humidifying enabled
Humidity Set programming phase
Running phase is in progress
Dripping or stopping phase is in progress
Setting of the duration of the cycle
o or n
n arrows within 10s.
o o
n n
Enter the Programming mode by pressing the SET %RH+ n
seconds. (°C or °F start flashing)
The instrument will show the first parameter present in "Pr1"
n for few
n n
n keys within 30 seconds.
n n
XLH360
cod. 1592017410
cod.
1592017410
cod.
cod.
1592017410
1592017410
7/16