Do not service this filter canister while under pressure!
We recommend maintaining a filtration inspection logbook to assist in
establishing a replacement schedule that is optimal for your fleet.
PneuClean should be mounted to the frame or stable platform by using the
two mounting brackets (P/N PC5003). These brackets are stainless steel 1.25"
X 8.00" in diameter, with feet and 7/16" pre-drilled holes.
When mounting vertically to the frame, the brackets are mounted
approximately 6-8" on center. The mounting brackets are to secure the filtration
unit to the tractor; allow at least 6" between the brackets in order to stabilize
the unit. There must be at least 20" between the end cap and the road surface
in order to remove the filter element.
When mounting horizontally to the frame, the brackets should be mounted
approximately 10"-15" on center. There must be at least 20" beyond the end
cap in order to remove the filter element for inspection or replacement. In most
installations, the quick disconnect coupling (with rain cap) can be used. There
should be some type of support for the hot hose, either on the tractor or on the
trailer.
NOTE: Neither the inlet or the outlet piping on the PneuClean unit were
designed or fabricated to hold non-supported hoses and/or piping. This can
void all warranties. Hot hoses and/or piping should be supported with
structurally sound brackets, which are not connected to the PneuClean units.
Before starting please inspect the unit for any damage which might have been
caused during shipping.
There are two primary places PneuClean filtration units can be mounted on
the road tractor or on the dry bulk trailer.
Tractor
When mounting PneuClean on the tractor, the units can be mounted either
horizontally or vertically this application offers an added benefit in that the filter
unit will act as a silencer if mounted within 24" of the blower discharge port.
Do not hard mount the filtration unit to the blower. A soft silicon pipe should
be placed between the two. When hard mounted blower vibration has caused
stress cracks along the side weldment of the inlet pipe on the filtration unit.
CAUTION!
PneuClean Mounting Information
40072PA R2