Clearwater Spas Genesis Blu Fusion Посібник

Переглянути онлайн або завантажити pdf Посібник для Система водопостачання Clearwater Spas Genesis Blu Fusion. Clearwater Spas Genesis Blu Fusion 2 сторінки. Salt system

Clearwater Spas Genesis Blu Fusion Посібник
MANUAL
Genesis Blu Fusion Salt System
MANUAL - Genesis Blu Fusion Salt System
CONTROLLER KEYPAD
For spas with a circulation pump:
• The control of the Blu Fusion Top Side is identical to the Blu Fusion 1 controller. The userinterface is as follows:
• To activate the topside control, any of the push button keys must be held down for the entire Key Lockout deactivation
sequence which takes several seconds.
• If the Key Lockout has been activated and any push button key is pressed, the three digit Seven Segment Display will display "Loc".
• After one second, the three digit Seven Segment Display will display a "3" in the center digit.
• The push button key must be held down until the three digit Seven Segment Display decreases to "1" and the power setting
is displayed, then bromine output or boost can be adjusted.
• The displayed count will be displayed as quickly as in 0.75 second intervals. If the depressed push button key is not released
within five seconds after the power setting is displayed, the Key Lockout will be reactivated preventing an accidental in-
crease or decrease in bromine production ( this is a precautionary – safety feature of the Blu Fusion TS System).
• After the power setting is displayed, the push button keys are activated and power setting is enabled (normal error code
display is also resumed). If any key remains depressed for five seconds during the deactivated Key Lockout period, the Key
Lockout will reactivate and disable control features.
• The Key Lockout will reactivate in 20 seconds after the last operational release of a push button key. The three digit Seven
Segment Display will display "Loc" for 0.5 seconds when Key Lockout is reactivated.
• Upon reactivation of the Key Lockout, the Topside Control Seven Segment Display will display the power setting along with
any active error codes or power setting LED displays. If the Electrode Current display feature is enabled, the Key Lockout will
not reactivate.
18800 Woodinville/Snohomish Rd. • P.O. Box 2140 • Woodinville, WA 98072 • p 425.483.1877 • f 425.487.1148 • www.clearwaterspas.com
cleaning out your spa plumbing 12-3-14.ind
Download this document at: clearwaterspas.com
LEGEND FOR CONTROLLER
"tdS" total dissolved solids
too high.
"OE" open element - detect
an inadequate connection.
"SE" shortened element
detects excessive current.
"bSt" boost key allows you
to boost the bromine.