6) Protection Switch
The Protection Switch is a circuit breaker. If the output is exceeded, the breaker will POP and you will have to manually reset it. This circuit
breaker will protect the inverter in case of Overload or short circuit. If you have to reset this breaker, you should verify the Startup and
Running current (listed on equipment) requirements for you equipment. Startup may be several times higher than the running rate, and may
cause this protection breaker to pop.
Example: air conditioners or air compressors have high startup ratings called Locked Rotor Amps (L.R.A.).
7) AC Terminal block (120V AC) *only available for 2000 watts and above.
This Terminal block is a convenient way of direct connecting equipment to achieve the full output power of the inverter. Be very careful as
these may be "hot" and if touched may cause severe injury and electrical shock.
Warning: It is recommended to have a professional electrician wire to these terminals. If they are touched, they may cause severe shock
and if wired incorrectly may cause permanent damage to the inverter and equipment, voiding warranty and in extreme cases may cause fire.
 Please see wiring diagram
8) Case ground Terminal
We recommend you use this terminal to ground the inverter case. It may be required for certain appliance's or equipment's safety
*Some home installations will require this please check local laws and code regulations. Marine and automotive may not apply.
9) Selectable frequency switch.
Selection is available between 60Hz and 50Hz. Convert and use according to the set frequency of the devices (60Hz is required in the U.S.
market)
Remote power switch terminal
10)
If you need to mount an ON/Off switch for the inverter in a separate location for your specific application, you can use the supplied adapter to
remotely locate any open/close ON/OFF switch that you choose.
.