11. Maintenance

Warning! Prior to any adjustment, maintenance or service work
disconnect the mains power plug!
11.1 General maintenance measures
- Keep all safety devices, air vents and the motor hous-ing free of dirt
and dust as far as possible. Wipe the equipment with a clean cloth or
blow it down with com-pressed air at low pressure.
- We recommend that you clean the equipment imme-diately after
you use it.
- Clean the equipment regularly with a damp cloth and some soft
soap. Do not use cleaning agents or sol-vents; these may be
aggressive to the plastic parts in the equipment. Ensure that no
water can get into the interior of the equipment.
- In order to extend the service life of the tool, oil the rotary parts
once monthly. Do not oil the motor.
11.2 Brush inspection
In case of excessive sparking, have the carbon brushes
carbon brushes should not be replaced by anyone but a qualified
electrician.
12. Storage
Store the device and its accessories in a dark, dry and frost-proof
place that is inaccessible to children. The optimum storage
temperature is between 5 and 30.C. Store the electrical tool in its
original packaging. Cover the electrical tool in order to protect it from
dust and moisture.
When the sawblade and key are not in use.
Store the operating manual with the electrical tool.

13. Electrical connection

The electrical motor installed is connected and ready for operation.
The connection complies with the applicable VDE and DIN
provisions. The customer's mains connection as well as the
extension cable used must also comply with these regulations.
- The product meets the requirements of EN 61000-3-11 and is
subject to special connec-tion conditions. This means that use of the
product at any freely selectable connection point is not al-lowed.
-Given unfavorable conditions in the power supply the product can
cause the voltage to fluctuate temporarily.
-The product is exclusively intended for use at con-nection points
that have a continuous current-carry-ing capacity of at least 100
Amper phase.
-As the user, you are required to ensure, in consulta-tion with your
electric power company if necessary, that the connection point at
which you wish to operate the product meets the specified
requirements.
Important information
In the event of an overloading the motor will switch itself off. After a
cool-down period (time varies) the mo-tor can be switched back on
again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
- Passage points, where connection cables are passed through
windows or doors.
- Kinks where the connection cable has been improp-erly fastened or
routed.
- Places where the connection cables have been cut due to being
driven over.
- Insulation damage due to being ripped out of the
wall outlet.
- Cracks due to the insulation ageing. Such damaged electrical
connection cables must not be used and are life-threatening due to
the insulation damage. Check the electrical connection cables for
damage regu-larly. Make sure that the connection cable does not
hang on the power network during the inspection. Electrical
connection cables must comply with the ap-plicable VDE and DIN
provisions. Only use connection cables with the marking .H05VV-F".
The printing of the type designation on the connection cable is
mandatory.
AC motor
- The mains voltage must be 230 V~
- Extension cables up to 25 m long must have a cross-section of 1.5
2
mm
.
Connections and repairs of electrical equipment may only be carried
out by an electrician. Please provide the following information in the
event of any enquiries:
Type of current for the motor
- Machine data - type plate
- Machine data - type plate