5.4.5.
Control of Flamer
HF-210 has 80 preset sequences, operator can use related channel DMX value or sequence No. to access certain sequence. Below is the
sequence list and single ignitions.
Single Ignition Sequence List:
No.
Ignition angle
1
-105°
2
-90°
3
-75°
4
-60°
5
-45°
6
-30°
7
-15°
8
9
15°
10
30°
11
45°
12
60°
13
75°
14
90°
15
105°
16
-105°
17
-90°
18
-75°
19
-60°
20
-45°
21
-30°
22
-15°
23
24
15°
25
30°
26
45°
27
60°
28
75°
29
90°
30
105°
Step Sequences List:
No.
Ignition angle NO.
31
Step from 1-15
32
Step from 15-1
33
Step 5>8>11
34
Step 11>8>5
35
Step 6>10
36
Step 10>6
37
Step 4>6>8>10>12
38
Step 12>10>8>6>4
39
Step 8>6>10>4>12
40
Step 8>10>6>12>4
41
Step 1-15
42
Step 15-1
43
Step 5>8>11
44
Step 11>8>5
Description
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Single Ignition SHORT flame
Description
SHORT flame Step sequence
SHORT flame
SHORT flame
SHORT flame
SHORT flame
SHORT flame
SHORT flame
SHORT flame
SHORT flame
SHORT flame
LONG flame Step sequence
LONG flame
LONG flame
LONG flame
Nozzle
Firing Duration
Movement
(For reference)
FirinDuration (For
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Nozzle
Firing Duration
movement
(For reference)
L -> R
R -> L
L -> R
R -> L
L -> R
R -> L
L -> R
R -> L
M>L>R>L
>R
M>R>L>R
>L
L -> R
R -> L
L -> R
R -> L
- 10 -
CH5 DMX
Reference Value
0.19s
3-5
reference)
0.19s
6-8
Duration (For
0.19s
9-11
reference)
0.19s
12-14
Duration (For
0.19s
15-17
reference)
0.19s
18-20
0.19s
21-23
0.19s
24-26
0.19s
27-29
0.19s
30-32
0.19s
33-35
0.19s
36-38
0.19s
39-41
0.19s
42-44
0.19s
45-47
0.56s
48-50
0.56s
51-53
0.56s
54-56
0.56s
57-59
0.56s
60-62
0.56s
63-65
0.56s
66-68
0.56s
69-71
0.56s
72-74
0.56s
75-77
0.56s
78-80
0.56s
81-83
0.56s
84-86
0.56s
87-89
0.56s
90-92
CH5 DMX
Reference Value
2.57 s
93-95
2.57 s
96-98
1.00 s
99-101
1.00 s
102-104
0.9 s
105-107
0.9 s
108-110
1.30 s
111-113
1.30 s
114-116
1.35 s
117-119
1.35 s
120-122
8.90 s
123-125
8.90 s
126-128
2.01 s
129-131
2.01 s
132-134