2. Connections
2.1.1 Electrical connection
Connect the fixture to the mains with the enclosed power cable and plug. The earth must be
connected.
Cable (EU)
Brown
Blue
Green/ Yellow
2.1.2 DMX connection
Take care to use only protected 3Pin or 5Pin XLR cables.
2.1.3 DMX connection with terminator
Where the DMX cable has to run a long distance or the equipment is operated in an
electrically noisy environment like a disco, for installations we recommend using a DMX
terminator. This prevents corruption of the digital control signal by electrical noise. The DMX
terminator is simply an XLR connector with a 120 OHM resistor between pins 2 and 3, which is
then plugged into the XLR output socket of the last device in the series. Please look to the
bottom drawings.
Cable (US)
Black
White
Green
Pin
Live
Neutral
Earth
7
International
L
N