TEST BENCH CONNECTIONS / OPERATION
• While bleeding the hose, hold the opposite end of the hose higher than the manifold block. This forces
the air out the end of the hose.
• Once a steady stream of water is exiting the end of the hose, either cap the end of the hose off or use
the needle valve included to close the end of the hose.
• Place the supplied rubber mat over the hose(s). This will help contain the hose and ends if a hose failure
occurs.
• Lower the tank lid and make sure the latch engages to ensure it is fully closed.
• Begin the test.
• Begin raising the air pressure regulator (Air Drive Throttle) until the desired test pressure has been
achieved.
Note:
The high pressure pump is driven by air pressure. As the air pressure is increased using the regula-
tor (throttle), the water pressure will increase. The more air pressure supplied, the higher the test pressure.
• When the test cycle is complete, check over the test result page and print the test receipt if desired.
Note:
Once the test result page has been passed, a test receipt can no longer be printed.
• Open the cabinet lid and remove the hose(s).