The SPD-3.4 smoke alarms are designed to detect smoky fires and issue both sound and light alarm
notifications.
The alarm operates as a standalone unit powered by DURACELL MN1604 (6LR61) batteries or an
equal one. It can be applied in residential and industrial premises.
The alarms can be interconnected with the help of two-wire line that allows to protect maximum
number of enclosed premises and to hear alarm sound in remote premises. The arrangement of
collective fire protection of a few flats is possible.
Features:
• Indication of standby mode (LED flashing every 35-45 sec);
• Indication of a low battery status (short sound and light signals every 35-45 sec);
• Indication of a fault or contamination of the alarm (short sound signals every 35-45 sec);
• Indication of alarm mode (loud intermittent sound signal, LED frequent flashing).
• Battery presence control.
1.1 Power voltage, V... ........................................................ 7,5-10,0
1.2 Alarm sound level at 3 m, dB.................................... ≥85
1.3 Interlink, pcs.................................................................... 10
1.4 Dimensions, mm.................... ...........................................Ø100х48
1.5 Weight (including battery), g......................................... 200
1.6 Operating temperature range, ° С ................................ from –10 tо 55
1.7 Average lifespan, years.................................................... ≥10
SPD-3.4 smoke alarm
Manual
Package
3. PREPARING FOR OPERATION, PLACEMENT AND INSTALLATION
3.1 Determine where the alarm will be sited taking into account the following requirements:
Alarms can be ceiling-mounted (not nearer than 10 cm from a wall);
-
wall-mounted (at the distance 10-30 cm from a ceiling).
It is prohibited to place alarms in bathrooms, shower rooms, W.C., laundries, saunas.
-
3.2 Unpack the alarm and check the package's content.
3.3 Detach the alarm from a base, turning it anti-clockwise and slightly pressing the rear side.
3.4 Install a battery into the battery compartment keeping polarity in accordance with the marks.
Check LED operating light flashes every 35-45 sec in standby mode.
3.5 Test the alarm for proper operating by pressing the test button located near the battery
compartment. The intermittent sound signal shall be heard and a light indicator shall flash.
3.6 Screw base to mounting surface after drilling two 4 mm holes in the base at marked places.
3.7 Attention! Secure the alarm to the base by mating the addendum on the alarm's rear side with
the base's slot 'key' marked
Check for proper operating after installation of a plastic or metal Ø<0,9 m pin-tester in the test hole
in the centre of the cover at the depth 10-15 mm for > 30 sec. The loud intermittent sound signal