AKO 14212 Інструкція
Переглянути онлайн або завантажити pdf Інструкція для Регулятор температури AKO 14212. AKO 14212 2 сторінки. Up to three relays and two probes
GB
1422H302 Ed.02
Temperature controller up to three relays and two probes
Devices designed to display, control and regulate cooling generators (manual or auto-
matic programmable defrosting).
1- Versions and references
MODEL
Cool: 16 A, 250 V, cos ϕ=1, SPST
8 A, 250 V, cos ϕ=1, SPDT
AKO-14212
R2:
Cool: 16 A, 250 V, cos ϕ=1, SPST
8 A, 250 V, cos ϕ=1, SPDT
AKO-14220
R2:
Cool: 16 A, 250 V, cos ϕ=1, SPST
8 A, 250 V, cos ϕ=1, SPDT
AKO-14223
R2:
Cool: 16 A, 250 V, cos ϕ=1, SPST
8 A, 250 V, cos ϕ=1, SPDT
AKO-14312
Def:
6 A, 250 V, cos ϕ=1, SPST
Fan:
Cool: 16 A, 250 V, cos ϕ=1, SPST
8 A, 250 V, cos ϕ=1, SPDT
AKO-14320
Def:
6 A, 250 V, cos ϕ=1, SPST
Fan:
Cool: 16 A, 250 V, cos ϕ=1, SPST
8 A, 250 V, cos ϕ=1, SPDT
AKO-14323
Def:
6 A, 250 V, cos ϕ=1, SPST
Fan:
2- Technical data
Temperature range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -50,0ºC to +99,9ºC
Resolution, Set Point and differential: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,1 ºC
Input for NTC probe: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AKO-149XX
Thermometric accuracy: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 1 ºC
Probe tolerance at 25 ºC: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 0,4 ºC
Maximum input power:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 VA
Working ambient temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -5 ºC to 40 ºC
Storage ambient temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -30 ºC to 70 ºC
Control device classification: Integrated mounting, with characteristic of automatic operation
Type 1.B action, to be used in a clean situation, logical medium (software) class A and con-
tinuous operation. Degree of contamination 2 on UNE-EN 60730-1
Double insulation between the power supply, the secondary circuit and the relay output.
Allocated pulse temperature:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2500 V
Pressure ball test temperature:
Accessible parts: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 ºC
Parts that position active elements: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 ºC
Voltage and current declared by the EMC tests:
Current of radio jamming supression test: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 mA
3- Installation
The controller should be installed in a place protected from vibrations, water and corrosive
gases, and where ambient temperature does not surpass the value specified in the technical
data.
In order for the controllers to have IP65 protection, the gasket should be properly installed
between the apparatus and the perimeter of the panel cut-out where it is to be fitted.
In order to give a correct reading, the probe should be installed in a place without heat
influences other than the temperature that is to be measured or controlled.
3.1 Fastening units for panel mounting:
max. 18 mm
PANEL CUT-OUT
70,5
3.2 Connection:
The probe and its lead should NEVER be installed in ducting along with power, control or
power supply wiring.
The power supply circuit should be connected with a minimum 2 A, 230 V, switch located
close to the unit. Power supply cables should be H05VV-F 2x0,5 mm
Section of connecting wires for relays contacts should be 2,5 mm
AKO-14212
8A
AKO-14220
16A
AKO-14223
2
3
4
5
6
7
8
9
10
C
R2
COOL
POWERSUPPLY S2-DEF
S1-TEM
RELAYS
POWER SUPPLY, 50/60 Hz
12 V – ~ ±20%
120 V ~+8% _ 12%
230 V ~±10%
12 V – ~ ±20%
120 V ~+8% _ 12%
230 V ~±10%
AKO-14223, AKO-14323: 207 V, 17 mA
AKO-14212, AKO-14312: 9,6 V,181 mA
AKO-14220, AKO-14320: 105 V, 36 mA
To fix the unit, place the faste-
ners 1 over the sliders 2 as
shown in the figure. Move the
fasteners in the direction of
the arrow. By pressing tab 3
fasteners may be moved in
the opposite direction of the
arrow.
61,5
2
or H05V-K 2x0,5 mm
2
.
AKO-14312
AKO-14320
6A
8A
16A
AKO-14323
1
2
3
4
5
6
7
8
FAN
C
DEF
COOL
POWERSUPPLY
S2-DEF
4- Front panel functions
LED COOL
Permanent: Cooling relay COOL (com-
pressor) energised.
Flashing: Because of the temperature
detected by Sensor 1 (TEM), the COOL
relay should be energised, but is no due to
a programmed parameter.
LED Fan
Permanent: FAN relay energised.
Flashing: Because of the temperature
detected by Sensor 2 (DEF), the FAN relay
should be energised, but is not due to a
programmed parameter.
LED Def
Permanent: Indicates defrost in opera-
tion.
LED Alarm
Permanent: Alarm indicator enabled.
Flashing: Alarm detected, but display
maintained.
DT LED
Indicates last defrost ended by time.
LED ºC
Permanent: Degrees ºC indicator.
5- Adjustment and configuration
It should only be programmed or modified by personnel who are fully conversant with the
equipment operation and possibilities.
5.1 Set Point temperature
The factory SET POINT default value is 0.0 ºC.
- Press
key for at least 5 seconds to DISPLAY SET POINT. It displays the CURRENT SET
POINT value and LED ºC or ºF starts flashing.
- Press
or
keys to CHANGE SET POINT into the required value.
- Pressing
+
keys simultaneously to ACCEPT THE NEW SET POINT. The display returns
to the CURRENT TEMPERATURE display status and LED ºC or ºF stops flashing.
When PA is displayed, PASSWORD programmed in L5 parameter of tid menu should be
entered to access the CURRENT SET POINT.
- Press
+
keys simultaneously. 0 will be displayed to ENTER PASSWORD.
- Press
or
keys to CHANGE NUMBER and DISPLAY PASSWORD programmed.
- Press
+
keys simultaneously to ACCEPT PASSWORD. The CURRENT SET POINT value
will be displayed and it can be already modified.
5 Sec.
CURRENT
PASSWORD
TEMPERATURE
REQUEST
5.2 Parameters configuration
Level 1
Menus
- Press simultaneously
we are in the programming LEVEL 1 MENUS and the first menu "rE" is displayed.
- Press
key to access the next menu and
- Pressing
+
keys in the last menu EP, the controller returns to the CURRENT TEM-
PERATURE display status and LED ºC or ºF will stop flashing
When PA is displayed, PASSWORD programmed in L5 of "tid" menu should be entered to
access programming LEVEL 1 MENUS.
- Press
+
keys. 0 will be displayed to ENTER PASSWORD
2
.
- Press
or
keys to CHANGE NUMBER and DISPLAY PASSWORD programmed.
- Press
+
keys simultaneously to ACCEPT PASSWORD. The first menu "rE" will be dis-
played.
Level 2
Parameters
- In the desired menu of LEVEL 1 MENUS, press
PARAMETERS programming is accessed. The first parameter of the selected menu is displa-
yed on the screen.
9
10
- Press
key to access the next parameter and
- Pressing
+
keys simultaneously in the last parameter EP, the controller returns to
the LEVEL 1 MENUS.
S1-TEM
Flashing: Programming phase.
LED ºF
Permanent: Degrees ºF indicator.
Flashing: Programming phase.
UP Key
- Press once to cancel the alarms, but they
remain displayed.
- When pressed for at least 5 seconds, a
manual defrost is started with program-
med duration.
- In programming, it makes the displayed
value increase.
DOWN Key
- Press once to cancel the alarms, but they
remain displayed.
- When pressed for at least 5 seconds, the
SP Set Point temperature is displayed.
- In programming, it makes the displayed
value reduce.
If P2=0 or L5=0
SIMULTANEOUSLY
SIMULTANEOUSLY
ENTER
DISPLAY
CURRENT
PASSWORD
PASSWORD
SET POINT
+
keys for at least 10 seconds. LED ºC or ºF will be flashing,
key to return to previous one.
+
keys simultaneously. LEVEL 2
key to return to the previous one.
SIMULTANEOUSLY
NEW
SET POINT