14. Error Code Chart
Code
E00
E01
Over-discharged
E02
E04
E05
Load Overload
E06
E08
Over-amperage
E10
E13
Reverse Polarity
E14
Reverse Polarity
*Please contact professions for technical support on additional troubleshooting.
Error
No Error
No action needed.
Battery voltage is too low.
Battery
DC load will be turned off until battery re-charges to
recovery voltage.
Battery voltage has exceeded controller limit.
Battery
Check battery bank voltage for compatibility with
Over-voltage
controller.
Load Short
DC load short circuit.
Circuit
DC load power draw exceeds controller capability.
Reduce load size or upgrade to a higher load capacity
controller.
Controller exceeds operating temperature limit.
Overheating
Ensure the controller is placed in a well-ventilated cool,
dry place.
Solar array amperage exceeds controller rated input
Solar
amperage.
Decrease the amperage of solar panels connected to the
controller or upgrade to a higher rated controller.
Solar array voltage exceeds controller rated input voltage.
Solar
Decrease the voltage of solar panels connected to the
Over-voltage
controller.
Solar
Solar array input wires connected with reverse polarity.
Disconnect and re-connect with correct wire polarity.
Battery
Battery connection wires connected with reverse polarity.
Disconnect and re-connect with correct wire polarity.
Description & Quick Troubleshoot