Options (Cont)
Push Bar
A switch-activated push-bar is wired into the magnetic lock and, when depressed, unlocks the magnetic switch (VSGX
only).
Card Reader Plate
A card-reader plate receiver is attached to the gate's frame. A 6" x 6" card-reader attachment plate allows a majority of
card readers to be attached.
Outlets for Rail Mounting
Connection points for Alvarado stainless steel rails can be installed in VSG latch and hinge posts.
Before You Begin
Use only skilled technicians for site preparation and installation of gate(s) using Alvarado's instructions.
Slab Requirements
The following requirements must be considered when selecting or preparing an installation location.
•
The gate must be installed on a level concrete pad at least 4" (102 mm) thick.
•
Do not attempt to install the gate on asphalt
•
The hinge and latch posts must be installed plumb with the floor while level and square to each other.
Space Requirements
The diagram below shows the gate footprint. Ensure there is sufficient space to install the gate at the desired location.
Power Requirements
VSGX gates require a low-voltage 12VDC power supply. A power transformer is included with each VSGX gate.
The installer is responsible for creating the necessary conduit runs to each gate installation location.
Environmental Requirements
•
This product is intended for indoor use only.
•
Recommended temperature range for operation: 0° to 50° C.
•
Recommended humidity range for operation: 5% to 95% (non-condensing).
Operating the unit outside the suggested range for temperature and humidity will result in degradation of
NOTE
performance and can damage the device.