Blue Angel BSE200 Інструкція з експлуатації та посібник із запчастин

Переглянути онлайн або завантажити pdf Інструкція з експлуатації та посібник із запчастин для Насос живлення Blue Angel BSE200. Blue Angel BSE200 4 сторінки. Sewer ejector pump

Operating Instructions And Parts Manual
Limited Warranty
For two (2) years from the date of purchase, Blue Angel will repair or replace, at its option, for the original
purchaser any part or parts of its Sump Pumps or Water Pumps ("Product") found upon examination by Blue
Angel to be defective in materials or workmanship. Please call Blue Angel (1-888-636-6628) for instructions or
see your dealer. Be prepared to provide the model number and serial number when exercising this warranty.
All transportation charges on Products or parts submitted for repair or replacement must be paid by
purchaser.
This Limited Warranty does NOT cover Products which have been damaged as a result of accident, abuse,
misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Blue
Angel's written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE.
THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL
DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or
limitations of incidental or consequential damages, so the above limitations might not apply to you. This
limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state
to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall
Blue Angel or its suppliers be liable for any special, consequential, incidental or penal damages including, but
not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to
associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power,
downtime costs, or claims of buyer's customers for such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty
claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call
Blue Angel (1-888-636-6628) for return authorization and instructions.
DO NOT MAIL THIS FORM TO BLUE ANGEL. Use this form only to maintain your records.
MODEL NO. ____________________
SERIAL NO. ____________________
INSTALLATION DATE ____________________
ATTACH YOUR RECEIPT HERE
www.blueangelpumps.com
8
Operating Instruction and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.
Sewer Ejector Pump
Description
The submersible pump is designed for
Danger indicates an imminently
home applications. The unit is
hazardous situation which, if not avoided,
equipped with a 3-prong grounding
will result in death or serious injury.
type power cord. Motor is oil-filled and
sealed for cooler running and designed
indicates a potentially hazardous
to operate under water. This pump is
situation which, if not avoided, COULD
not suitable for aquatic life.
result in death or serious injury.
Unpacking
Inspect this unit before it is used.
Caution indicates a potentially
hazardous situation which, if not
Occasionally, products are damaged
avoided, MAY result in minor or
during shipment. If the pump or
moderate injury.
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
Notice indicates important information,
result in serious injury or death.
that if not followed, may cause
damage to equipment.
Important Safety
General Safety
Instructions
Information
READ AND FOLLOW ALL INSTRUCTIONS.
Safety Guidelines
CALIFORNIA PROPOSITION 65
This manual contains information that is
very important to know and understand.
This product or its power cord may
This information is provided for SAFETY
contain chemicals known to the State
and to PREVENT EQUIPMENT PROBLEMS.
of California to cause cancer and birth
To help recognize this information,
defects or other reproductive harm.
Wash hands after handling.
observe the following symbols:
Specifications
Power supply requirements
BSE50 . . . . . . . . . . . . . . . . . . . . . .120V, 60 hz
BSE75, BSE100, and BSE200 . . . .240V, 60 hz
Motor . . . . . . . . . . . . . . . . . . . . . . .Single phase, oil filled
Horsepower/Current
BSE50 . . . . . . . . . . . . . . . . . . . . . .1/2 HP, 12 A
BSE75 . . . . . . . . . . . . . . . . . . . . . .3/4 HP, 7 A
BSE100 . . . . . . . . . . . . . . . . . . . . .1 HP, 8.5 A
BSE200 . . . . . . . . . . . . . . . . . . . . .2 HP, 12 A
Liquid temperature range . . . . . .40°F to 120°F
Circuit requirements . . . . . . . . . . .15 amps (min)
Dimensions . . . . . . . . . . . . . . . . . . .11
1
/
" high x 9
3
/
" base
2
4
Cut-in level (factory set) . . . . . . . .13"
Cut-out level (factory set) . . . . . . .7"
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2007 Blue Angel™ Pumps
For parts, product & service information
visit www.blueangelpumps.com
BSE50, BSE75, BSE100, BSE200
GENERAL SAFETY INFORMATION
Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
Warning
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.
This pump is not designed to handle salt
water, brine, laundry discharge or any
other application which may contain
caustic chemicals and/or foreign materials.
Pump damage could occur if used in these
applications and will void warranty.
All wiring must be performed by a
qualified electrician.
If the basement has water or
moisture on the floor, do not
walk on wet area until all
power is turned off. If the shut-off box
is in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.
Construction
Motor housing . . . . . . . . . . . .Cast Iron
Volute . . . . . . . . . . . . . . . . . . .Cast Iron
Impeller . . . . . . . . . . . . . . . . . .Glass reinforced thermoplastic
Shaft . . . . . . . . . . . . . . . . . . . .Low carbon steel
Seals . . . . . . . . . . . . . . . . . . . .Buna N
Discharge . . . . . . . . . . . . . . . .1
1
/
" NPT
2