6.4 EDID Management
This unit uses an EDID Manager application which allows the user to
copy the EDID from an attached display, edit an existing EDID file
stored on the PC or create a basic EDID from scratch. The EDID can
then be uploaded to the unit for use. Please obtain the EDID Manager
software from your authorized dealer and save it in a directory where
you can easily find it. Once the file has been downloaded successfully,
double click to execute the application and the EDID Manager's
window will pop- up.
After launching the software, power the unit on and then connect it
to the PC/laptop using a USB cable. Click on the "Search" button to
detect and connect to the unit. If the unit is successfully connected
the "Search" button will become greyed out and the circle within
the "Link" section will turn green with the connected model's name
displayed next to it. When you are finished controlling the unit please
press the "Disconnect" button.
6.4.1 EDID Controller
Within the "EDID Controller" tab, the user may select the EDID for the
unit to use (Internal, External or User). The selection will immediately
occur on the unit and the unit's LED lights will change accordingly.
A stored User EDID may be uploaded from the local PC by first
clicking the "Open" button to load the EDID's .bin file from your PC
into the software, and then pressing the "Upload" button to upload