Acquaer SEC075T-1 Посібник користувача - Сторінка 3

Переглянути онлайн або завантажити pdf Посібник користувача для Водяний насос Acquaer SEC075T-1. Acquaer SEC075T-1 9 сторінок. Submersible sewage pump
Також для Acquaer SEC075T-1: Посібник користувача (15 сторінок)

Acquaer SEC075T-1 Посібник користувача
PIÈCES SCHÉMA
1
3
4
5

LISTE DES PIECES

La description
Numéro de pièce
1
couvercle supérieur
interrupteur à flotteur de ferroutage
2
cage du moteur
3
4
corps de la pompe
5
14
2
impelleur

SAFETY INFORMATION

This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for
a long time when properly installed, maintained, and used. However, inadequate electrical power to the
pump, dirt, or blockage by ice or debris may cause the pump to fail, eventually bringing about additional
water damage. To minimize the potential for water damage due to pump failure, please carefully read
the manual and follow the instructions regarding common pump problems and remedies or call
1-888-538-0082.
This pump has not been tested or approved for use in swimming pools or in salt-water marine areas.
It is also not engineered to be run continuously as a "fountain" or "waterfall" pump. Because this
pump has an oil-filled motor, it should NOT be used in water containing fish. Pump only water with
this pump.
For safety, the pump motor has an automatic resetting thermal protector that automatically will turn off
the pump if it becomes too hot. Overuse of this feature will damage the pump and will void the
warranty.
Once the thermal protector detects that the pump has cooled to a safe temperature, it will allow the pump
to operate normally. If the pump is plugged in, it may restart unexpectedly.

ADDITIONAL SAFETY PRECAUTIONS

1.
Know the pump applications, limitations, and potential hazards.
2.
Make certain the electrical power source is adequate for the requirements of the pump.
ALWAYS disconnect the power to the pump before servicing.
3.
Release all pressure (drain all water) within system before servicing any component.
4.
5.
Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
Secure the pump on a solid base to keep the pump vertical and above mud and sand during operation
6.
7.
to maximize pumping efficiency and prevent clogging and premature pump failure.
8.
Check that all pipe connections are tight to minimize leaks.
Connect the pump DIRECTLY to a grounded, GFCI outlet.
9.
Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life
threatening safety hazard if the insulation becomes damaged or the connection ends fall into water.
10.
Make certain the electrical circuit to the pump is protected by a 15 Amp or larger fuse or circuit breaker.
Periodically inspect the pump and system components to be sure the pump inlets are free of mud, sand,
11.
and debris. DISCONNECT THE PUMP FROM THE POWER SUPPLY BEFORE INSPECTING.
Wear safety glasses at all times when working with pumps.
12.
13.
Follow all electrical and safety codes, particularly the National Electrical Code (NEC) and in the
workplace, the Occupational Safety and Health Act (OSHA).
This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved
14.
3-conductor cord and 3-prong grounded plug. DO NOT REMOVE THE GROUND PIN UNDER ANY
CIRCUMSTANCES. The 3-prong plug must be directly inserted into a properly installed and grounded
3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the
2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with
the National Electrical Code and local codes and ordinances. All wiring should be performed by a
qualified electrician.
Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord.
15.
Do not use damaged or worn cords.
3