If the monitor is installed in areas where freezing can occur, a valve should be installed below the frost line which will allow the monitor to be fully
drained after use. Additionally, the valve on the monitor should be opened and closed a few times to make sure any residual water is allowed to drain out
of the valve body.
CAUTIONS:
Your monitor and nozzle should be inspected prior to and after each use to ensure it is in good operating condition. Periodically, an unanticipated incident
occurs where the unit is misused in a manner that is inconsistent with standard operating practices. A partial list of potential misuses includes:
• Operating above maximum rated pressure or flow.
• Not draining the monitor above and below the valve and allowing water to freeze in the unit.
• Prolonged exposure to temperatures above 140 degrees F, or below 32 degrees F.
• Operating in an extremely corrosive environment.
• Other misuse that may be unique to your specific environment.
Also, there are many "tell tale" signs that indicate repair is in order, such as:
• A handle that is inoperable or difficult to operate.
• Excessive wear.
• Poor discharge performance.
• Water leaks.
If any of the above situations are encountered, the monitor should be taken out of service, repaired and tested by a qualified technician before placing it
back in service.

MAINTENANCE INSTRUCTIONS:

• Periodically lubricate the grease fittings with Lubriplate Low-Temp or equivalent.
Inject the lubricant until it becomes visible from the bleeder holes in the center of the swivel plugs.
• Periodically clean grit and dirt from around exterior moving parts.
• Periodically operate all functions of the monitor through its full travel.
• The brake mechanism on the horizontal and vertical travel may require periodic maintenance. To check the
adjustment, rotate the brake knob counterclockwise until it stops. Turning the brake knob clockwise 1 to 1 1/2
turns should lock the monitor. If the monitor does not lock, remove the lock mechanism, inspect for wear and
replace components as necessary.
• Replace the identification tag if it is worn or damaged.
Replace the seals in the ball valve if water leaks are observed.
ISO 9001 REGISTERED COMPANY
PHONE: 330.264.5678 or 800.228.1161 I FAX: 330.264.2944 or 800.531.7335 I akronbrass.com
WARRANTY AND DISCLAIMER: We warrant Akron Brass products for a period of five (5) years after purchase against defects in materials or workmanship. Akron Brass will repair or replace product
which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service.
We will not be responsible for: wear and tear; any improper installation, use, maintenance or storage; negligence of the owner or user; repair or modification after delivery; damage; failure to follow
our instructions or recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT,
AND WE DISCLAIM ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, incidental or
indirect damages (including, but not limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty.
© Akron Brass Company. 2000 All rights reserved. No portion of this can be reproduced without the express written consent of Akron Brass Company.
revised: 6/12