Trouble Shooting
Symptom
No water is delivered
from the pump, or pump
performance is decreased.
No water is delivered from
mains.
Pump continually runs.
AcquaSaver warranty for Australia and New Zealand
The AcquaSaver Valve is guaranteed for a period of 2 years from the date of original purchase to be free of
material or manufacturing defects. Should any part fail as a result of such defects within this period, the
AcquaSaver valve will be repaired or replaced free of charge. The AcquaSaver also has a LIMITED LIFETIME
WARRANTY on all brass components. Any brass component will be replaced free of charge if it fails in normal
use during its life. The warranty applies in all states and territories in Australia and New Zealand. The warranty
period commences on the day of the original purchase of the AcquaSaver valve. Evidence of this purchase
must be provided when claiming repairs or replacement; it is recommended you retain all receipts.
Both warranties are subject to conditions by the original purchaser with all conditions set in the installation
and operating instructions. Failure to comply with these instructions, damage or breakdown caused by fair
wear or tear, negligence, misuse, incorrect installation, chemical or additive in the water, corrosive or abrasive
water, inadequate conditions, attempting repairs or accidents are not covered by this warranty.
Proudly manufactured by
6
4
Cause
Rainwater tank is empty.
No Power.
Isolation valve is closed.
No water from mains.
Debris in the valve.
Leak in the plumbing system.
e.g. toilet or tap is leaking.
Faulty pump
4 Squires Way, Croydon South
Victoria 3136 Australia
Parts List
Item No.
QTY
Part Name
1
1
Acquasaver Tank Cover - Top
2
1
Acquasaver Tank Cover - Base
3
1
Acquasaver Valve
4
2
Right Angle Ball Valve (Watermark Approved)
5
1
Rubber Washer
6
3
Plastite Screws
Remedy
Wait for tank to fill.
Check power supply & plug.
Open Isolation valve.
See pump manual.
Check isolation valve
Contact dealer.
Contact plumber
Contact pump manufacturer.