3. Field Installation Checklist
☐ The Central unit and access control panel need a common ground.
☐ The Remote unit and card reader need a common ground.
☐ The top of each unit (where antennas are located) should point toward the sky.
☐ The Central and Remote units should be installed level relative to each other.
☐ There should be a direct line of sight between Central and Remote units (if there is no direct line of sight,
a Repeater unit is recommended).
☐ Both the Central and Remote units should be mounted high enough to avoid interference from obstacles
(vehicles, trains, buildings, trees, etc.).
☐ Metal mounting surfaces are not recommended. If use of a metal surface is unavoidable, space unit as far
from metal surface as possible using non-metal spacer.
☐ Enclosure locking screws (6-32 x 3/8) max torque rating 8.5 inch-pounds.
Central and Remote Connections
If troubleshooting is necessary, see manual.
Typical Suprex® RF Central and Remote Wiring Connections
DC Power
Supply
DC Power
Supply
Power
Ground
Access
Control
Access
Panel
Control
Panel
Ground
LED Out
Data1
Data 0
COM
DC Power
Supply
DC Power
Supply
Power
Ground
Card
Reader
Card
Power
Reader
Ground
LED IN
Power
Data 1
Ground
Data 0
LED IN
Data 1
Data 0
10/26/2020
Typical S
Typical S
Central and Remote Connections
SPX-5631 / 5641 Central
SPX-5631 / 5641 Central
Power
Ground
Ground
LED Out
Data1
Data 0
N.O.
COM
N.O.
SPX-5631 / 5641 Remote
SPX-5631 / 5641 Remote
Power
Ground
Complete documentation PDFs at CypressIntegration.com
Series
Series
+8 to +16 VDC
Ground
+8 to +16 VDC
Ground
LED In
Data 1
Data 0
LED In
Data 1
Data 0
+8 to +16 VDC
Ground
+8 to +16 VDC
Ground
R1 N.O.
R1 COM
R1 N.C.
LED OUT
Data 1
Data 0
LED OUT
Data 1
Data 0
Ground
Ground
R1 IN
R1 IN
Door
R1 N.O.
Strike
R1 COM
Door
Output
R1 N.C.
Strike
Output