Ambirad Apollo QH 45-1 Інструкція з експлуатації - Сторінка 7
Переглянути онлайн або завантажити pdf Інструкція з експлуатації для Обігрівач Ambirad Apollo QH 45-1. Ambirad Apollo QH 45-1 20 сторінок. Quartz glow instant infra-red heaters
• When hanging from a ceiling two chains of
equal length and gauge are required and
should be selected with fixings that are more
than adequate to hold the weight of the
heater. Ensure minimum distance from
ceiling is adhered to as shown below. If in
doubt contact a professional for advice!
1. Fix the heater assembly to the chains via the
hole in the centre of the joining bar as shown
below and ensure the heater faces directly
down when hanging.
Wall mounting two SOR 15's ONLY
1. Securely fasten the L-shaped wall brackets
to the mounting surface using both of the
fixing holes in the short part of the bracket .
Refer
to
Table
positioning of the heater. Please note. wall
fixings are not supplied. They should be
selected to substantially support the weight
of the installation. If in doubt contact a
professional for advice! .
2. Fix the heater assembly to the brackets via
the hole in the centre of the joining bar. The
joining bars should slide inside the gap of
the two wall brackets
3. Place a bolt and washer in the hole of the
wall bracket and put a serrated washer on
the opposite side between the bracket and
joining bar. Repeat on opposite side.
4. Fit the heater assembly to the brackets and
place a washer and nut on the bolts
protruding through the joining bars.
5. Fully tighten the nut and bolts with the heater
set at the desired angle shown opposite
1
for
recommended
• SOR 15 ONLY - When vertically mounting,
ensure the mounting surface is angled so
the heater projects downwards. Do not
position the heater at an angle more than
45° and less than 30° to the horizontal as
shown below. Position the heater so the cord
is exiting the terminal box pointing down
1.3.2.4 Three SOR 15/DL30 units
• Three Sorrento heaters can be joined
together and can be hung from a ceiling from
chains (not supplied). In addition, the SOR15
can
be
wall
mounted
vertically. DO NOT WALL MOUNT THE
SORDL30 UNIT!
• When wall mounting three SOR15 heaters
horizontally, do not position the heater at an
angle more than 80° and less than 60° as
shown on next page.
• When hanging from a ceiling four chains of
equal length and gauge are required and
should be selected with fixings that are more
than adequate to hold the weight of the
heater. Ensure minimum distance from
ceiling is adhered to as shown below. If in
doubt contact a professional for advice!
horizontally
or