Askoll PURE XL HC LED Gebrauchsanweisung - Seite 9
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Aquarien Askoll PURE XL HC LED herunter. Askoll PURE XL HC LED 14 Seiten. Marine aquarium kit
Auch für Askoll PURE XL HC LED: Gebrauchsanweisung (14 seiten)
PURE Aquarium KIT
utes of inactivity. The locked status is signaled by the "bloc" message
that appears as soon as the block is activated and at each subse-
quent pressing of any keys. To remove the locked status and access
the timer functions, it is necessary to press the
quickly in sequence. Unlocking is confirmed by the appearance of
4 dashes on the clock digits for a few moments. If during the pro-
gramming phase the current time or the on/off times settings are not
completed, the lock will not activate after 3 minutes of key inactivity.
There is also a demo mode (DEMO), which simulates the complete
daily cycle in a few seconds to highlight the potential off the led
lighting system when controlled by the integrated timer (point F).
IMPORTANT
Turning the light off manually with the button
turning the light off automatically at the set time do not disconnect
the lighting unit from the power supply.
The PURE
aquarium timer does not need batteries. If there is a
LED
mains power failure, the system maintains the user settings for at
least 12 hours.
A. Setting the clock time on first start up (hours and
minutes)
Once the lighting unit is connected to the power supply, the timer
waits for the time to be set (it displays icon
digits flash).
1) Set the hour by pressing
setting. Then press
2) Set the minutes by pressing
the setting. Press
to confirm. The time has now been set.
If you do nothing, the lighting system is set by default to turn on at
10:00 and turn off at 18:00. To set the on/off times to your preference
or to set the only manual mode, refer to point C.
B. Manual mode
Press
to turn on the day light (
on) and turn the light off completely, in that sequence.
C. Programming the automatic light on/off times
1) Unlock the timer by pressing the
in sequence.
2) Hold down button
until the text "light" displays (wait for the
countdown 3..2..1 "light" to terminate).
3) The time digits will now display "Auto" and icons
flash. To set the only manual mode, press
displays. Confirm by pressing
4) Once you have set automatic mode "auto", icon
digits will flash. Set the on time (hour and minutes) in same way
as for the clock time (points 1 and 2, par. A).
5) Once you have set the on time, icon
flash. Set the off time (hour and minutes) in same way as for the
clock time (points 1 and 2, par. A).
6) Once you have finished, the timer will display the clock time
again.
10
,
on the Timer and
and the two hour
to increase and
to decrease the
to set the minutes.
to increase and
icon on), the night light (
,
and
until the text "man"
.
and the hour digits will
7) The timer is now programmed to run the automatic daily light
cycle, as indicated at the start of this chapter.
D. Changing the clock time (hours and minutes)
and
keys
If you need to change the clock time, proceed as follows:
1) Unlock the timer by pressing the
in sequence.
2) Press and hold down
must wait for 2 countdowns to complete: 3..2..1 "light"
3..2..1 "time").
3) The icon
(hours and minutes) as indicated in par. A.
E. Turning the RFT function on and off
The RFT is on by default (On). To turn it on/off, proceed as follows:
1) Unlock the timer by pressing the
in sequence.
2) Press and hold down
must wait for 3 countdowns to complete: 3..2..1 "light"
3..2..1 "time" 3..2..1 "RFT").
3) The clock digits display "On" and icon
deactivate (OFF) or activate (ON) the RFT function. Confirm by
pressing
4) Once you have finished, the timer will display the clock time
again.
When the RFT function is on, the timer will flash every 15 days to
remind you to do scheduled maintenance. To reset the indication,
press
.
F. Turning the DEMO function on and off
1) Unlock the timer by pressing the
to decrease
in sequence.
2) Hold down buttons
its display "DEMO" (you must wait for the countdown 5..4..3..2..1
"DEMO" to terminate). The DEMO function is now active.
3) To turn DEMO mode off, press
time again.
G. Restoring the factory defaults (timer reset)
icon
1) Unlock the timer by pressing the
in sequence.
2) Press and hold down buttons
keys quickly
the clock digits display "RSET" (you must wait for 2 countdowns
to complete: 5..4..3..2..1 "DEMO" 5..4..3..2..1 "RSET").
3) The timer will now restore the factory default settings.
5.1.2. Filtration
and
will
and the hour
Aquarium water, to provide the best habitat for fish and plants, must
be filtered continuously with mechanical, biological and chemical
filtration.
until the clock digits display "time" (you
and the hour digits will flash: set the clock time
until the clock digits display "RFT" (you
.
and
simultaneously until the clock dig-
. The timer will display clock
and
CAUTION
Always close the filter cover after the necessary oper-
ations have been performed, to prevent algae growing
on the filters due to their exposure to direct light.
,
and
keys quickly
,
and
keys quickly
flashes; press
to
,
and
keys quickly
,
and
keys quickly
simultaneously until