ACR STOVES Solis SOLMF Technisches Handbuch - Seite 12

Blättern Sie online oder laden Sie pdf Technisches Handbuch für Herd ACR STOVES Solis SOLMF herunter. ACR STOVES Solis SOLMF 17 Seiten.

ACR STOVES Solis SOLMF Technisches Handbuch
Problem
Fire difficult to
start / goes out
Fire burns too quickly
Smokes on initial
lighting
Smokes while burning
Low heat output

Troubleshooting

Probable Cause
• Green wood / wet wood
• Logs are too large
• Not enough primary air
• Insufficient draft
• Too much draft
• Excessive draft
• Flue is cold
• Insufficient draught
• Poor quality wood
Action Recommend
Use hardwood logs with a maximum
moisture content of 20%
Use kindling and small logs to start the
fire and once established use split logs
Open air control
Check the flue is not obstructed
Reduce the air control
Install a draft stabiliser
Burn paper and kindling to increase
heat in flue
Check the flue is not obstructed
Use seasoned Hardwood (this has a
Higher calorific value)