OPERATION
Notice For best result, use an approved tire bead lubricant before removing or installing tire on rim.
1. Remove the wheel from the vehicle and secure on a suitable work surface. Fully deflate the tire, re-
move valve core, and all balance weights.
2. Hold and position the bead breaker under the rim flange. Position the claw on the inner part of the rim,
with the bead breaker feet against the outer part of the rim (refer to figure 1).
3. Operate the pump to close the claw portion and simultaneously press against the bead surface. To
stop or hold, simply cease pump operation.
4. With the claw pushing against the inner part of the rim, the shovel and feet push against the lateral
ring and the bead of the tire.
5. Continue operating the pump until the bead separates from the tire rim surface.
6. To release, simply release the hydraulic pressure of pump by opening the release valve on the pump
or if a treadle pump, actuate the release pedal.
7. Continue this operation around both outboard and inboard sides of the rim until the bead is free.
MAINTENANCE
Important:
Use only good grade hydraulic oil. Do
not mix different types of fluid and NEVER use brake
fluid, turbine oil, transmission fluid, motor oil or glyc-
erin. Improper fluid can cause premature failure of the
jack and the potential for sudden and immediate loss
of load. Mobil DTE 13M or equivalent recommended.
Inspect the bead breaker before every use for cracks
or physical damages, leaks, worn or missing parts.
Do not use the bead breaker with damaged or miss-
ing parts, or oil leaks.
Lubrication
A periodic coating of light lubricating oil to pivot
points, axels and hinges will help to prevent rust.
Cleaning
Keep the hydraulic system as free of dirt as possible. When not in use, couplers or connections must be
sealed with dust covers
Periodically check the bead breaker for signs of rust or corrosion. Clean as needed and wipe with an oily
cloth.
Storage
When not in use, store the bead breaker with cylinder fully retracted.