Blättern Sie online oder laden Sie pdf Einbauanleitung für Sanitärprodukt American Standard TownSquare Pressure Balancing Bath and Shower 2555.652 herunter. American Standard TownSquare Pressure Balancing Bath and Shower 2555.652 3 Seiten. Pressure balancing bath and shower with built-in diverter for rim mount tub filler with everclean finish

American Standard TownSquare Pressure Balancing Bath and Shower 2555.652 Einbauanleitung
4
INSTALL HANDLE AND DIVERTER KNOB
Install HANDLE BUSHING (1) onto CAP (2).
Find correct position of HANDLE (3) and push
HANDLE (3) onto VALVE STEM (4).
Install HANDLE SCREW (5) and push in INDEX CAP (6).
Check proper operation of HANDLE.
Screw DIVERTER KNOB (7) onto Diverter stem.
7
5
6
1
4
3
6
TO GAIN ACCESS TO VALVE FOR SERVICING
Pull INDEX CAP , unscrew HANDLE SCREW and pull HANDLE off valve stem.
Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON. Remove COVER by pulling straight out.
Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve, if present.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.
Turn on water supply and see above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair
Part M952100-0070A if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).
6
8
7
5
7
EverClean™ Finish Care Instructions
American Standard's EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with
clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
2
4
1
3
2
9
5
ADJUST HOT LIMIT STOP
By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting)
before making adjustment to HOT LIMIT STOP (1). Use a flat
blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot
water temperature. Use ARROW (3) on CARTRIDGE (4)
and NUMBERS (5) on HOT LIMIT STOP (1) for
indication.
3
2
LARGE OUTLET
5
INLETS
3
5
1
0 1 3 5 7 9 11 13 15
4
4
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
˚
ROTATE 180
BACK TO BACK INSTALLATION
2
HOTTER
(Smaller Numbers)
5
1