American Standard Fluent 7186.910 Installations- und Betriebshandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Installations- und Betriebshandbuch für Badewannen American Standard Fluent 7186.910 herunter. American Standard Fluent 7186.910 14 Seiten. Bath waste and overflow with toe tapper drain plug & deck mount bath filler
3
VALVE ASSEMBLY
• Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks.
• Slide HOSE CONNECTOR (10) onto VALVE BODY (4). Slide
HOSE CONNECTOR G1/2 (11) onto TEE (5) Slide HOSE (3)
assembly into opening of both VALVE BODIES (4) and TEE (5).
Tighten HOSE CONNECTOR (10) and (11) firmly.
• Threads of VALVE BODY (4) should extend at least 5/16 inch
above MOUNTING SURFACE (8). If necessary, adjust
LOCKNUT (1).
• Place RUBBER RING (7) into ESCUTCHEON (6) and thread
onto valves until snug against internal stop.
• Tighten LOCKNUT (1) to secure VALVE (4)
position with channel locks.
• Connect HOT water supply to inlet of left VALVE
and COLD water supply to inlet of right
VALVE using appropriate connector.
4
DIVERTER INSTALLATION
NOTE: Use thread sealant on all threaded connections.
• Assemble MOUNTING NUT (7) and WASHER (8) onto
DIVERTER BODY (6).
• Insert the DIVERTER BODY (6) through the mounting deck
from below. Place RUBBER RING (10) into ESCUTCHEON (9)
and thread onto DIVERTER BODY THREADS (6) until snug
against internal stop.
• Position the DIVERTER BODY (6) as required and tighten the
MOUNTING NUT (7) securely.
• Connect the water inlet and tub outlet lines to the DIVERTER
BODY (6).
• Thread HOSE (4) into the SHOWER CONNECTION (5) of the
DIVERTER BODY (6) and tighten securely. Check with local
plumbing codes for backflow prevention requirements.
Install a backflow prevention device if required.
7
5/16'' MIN.
4
6
7
10
HOT
4
6
3
8
MOUNTING
SURFACE
2
1
FITTING
MOUNTING
SURFACE
TUB OUTLET
- 2 -
8
MOUNTING
SURFACE
6
7
11
11
5
10
9
10
8
7
6
WATER INLET
FROM TEE
5
4
M965798 Rev. 1.0 (3/17)
COLD