Doorentryonline SR2-X Benutzerhandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Kartenleser Doorentryonline SR2-X herunter. Doorentryonline SR2-X 12 Seiten. Proximity, wiegand & mifare card reader with remote control
Add Visitor Users via the Remote Control
Up to 10 Visitor Users can be added and allowed no more than ten times of usage until they are
automatically invalid. The USER ID numbers must be 990-999 for this function to operate
Programming Step
1. Enter Program Mode
2. Add PIN
OR
3. Add Card
4. Exit Program Mode
Delete User Cards or PIN code Via the Remote Control
Programming Step
1. Enter Program Mode
2. Delete Card/PIN: By read card
OR
3. Delete Card: By User ID
number
OR
4. Delete Card: By Card Number
OR
5. Delete all users
6. Exit Program Mode
Set Relay Configuration Via the Remote Control
The relay configuration sets the behavior of the output relay on activation
Programming Step
1. Enter Program Mode
2. Pulse Mode
OR
3. Latch Mode
4. Exit Program Mode
Remote Control Operation
* (Master Code) #
1 (User ID) # (0-9) # (Enter PIN number, 4-6 digits)
#
1 (User ID) # (0-9) # (Present Card) #
The user ID numbers must be from 990-999
(0-9) Means the number of usage times – 0=10 times
*
Remote Control Operation
* (Master Code) #
2 (Present Card/Or enter Pin code) #
Repeat step 2 for additional user cards before pressing the
#
2 (Enter user ID number) #
The user ID is any number from 0-986
2 (Input the 8/10 digits Card number) #
2 (Master Code) #
*
Remote Control Operation
* (Master Code) #
3 (1-99) #
The relay time is 1-99 seconds. (1=50ms) Default is 5
seconds
30 # Sets the relay to ON/OFF Latch mode
*