The SR2-X's alarm trigger is activated by an LDR (Light Dependent Resistor) which is located to the rear left
side of the unit as illustrated below
The alarm function is designed as an 'Anti-Theft' facility which cannot be disabled but it can be stopped by
presenting a valid card or key fob to the reader or entering the Master Code followed by the # sign via the
remote
Alternatively, you can prevent the alarm from activating by covering the LDR with a non-light absorbent
substance. Black paint or a small amount of 'Blu-Tack' will work perfectly fine
This is the LDR (Light
Dependent Resistor).
The LDR is the SR2's
Alarm Trigger Sensor
and activated by light