Astrapool Viron Installations- und Betriebsanleitung - Seite 8
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Controller Astrapool Viron herunter. Astrapool Viron 20 Seiten. Connect pool and spa controller
SETTING THE TEMPERATURE
From the main menu, select the HEATING icon
o
Your screen will show current and set temperatures
LIGHTING OPERATION
From the main menu, select the LIGHTING icon
o
Your screen with show all available lighting zones. You can select ON / OFF or AUTO modes
for the lights.
o
For systems using AstralPool Delta LED lighting, you can change colour settings from this
menu also.
3 SPEED VIRON P300 (OPTIONAL - NOT INCLUDED)
The Genus IV control system has the ability to control the speed of the Viron P300 3 speed high efficiency pump.
The advantage of the Viron P 300 is its extremely low operating costs, reduced CO2 emissions and low operating
noise.
The speed of the Viron pump is controlled via the touch pad on the motor of the pump.
However, your Viron Connect Control system will allow speed control of your pump via the touchscreen console.
When a Viron P300 pump is installed, the filter timeclock period should ideally be set for 12 hours per day. For
example, set the on period for 0800 hours and the operating hours for 12 hour operating period. In this case, the
pump will turn on at 8.00 am and turn off at 8.00 pm.
Do not set the pump timer period to span midnight.
Refer to Viron Pump instructions for explanation of the operation and speed settings of the Viron Pump.
1. The Viron P 300 has 3 speed settings – low, medium and high. High Speed should be used when
vacuuming the pool or operating spa jets or some water features such as water falls. Medium speed can
be used for gentle spa jet action, or filtration for the pool. Low speed is the recommended setting for
everyday filtration of your pool.
2. The Viron P300 will automatically start on high speed for the first 5 minutes to assist in priming and
substantially fill the hair and lint pot with water.
was set at before it was turned off.
3. During normal operation, it is recommended that the pump be operated on low speed for 12 hours per day.
This will achieve the lowest operating costs with the lowest noise level. Should your pool have areas
where water is not turning over when pump is on low speed, increase the speed setting.
Inst 276 - Viron Connect Pool & Spa Controller V0610
To change pool temperature setting, select POOL and use up and down arrows to set
temperature
To change spa temperature setting, select SPA and use up and down arrows to set
temperature.
After 5 minutes the pump will revert to the last speed it